Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-98-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
continuously even during the magnetic flux period. So
the magnetic flux can be used in the motor stop, as
well as to change the rotation speed of the motor. Its
other advantages are:
Brake immediately after the stop command. It does
not need to wait the magnetic flux weaken.
Better cooling for motors. The current of the stator
other than the rotor increases during magnetic flux
braking, while the cooling of the stator is more
effective than the rotor.
P08.51
Input power
factor of the
inverter
This function code is used to adjust the displayed
current of the AC input side.
Setting range: 0.00~1.00
0.56
○
P10 Group Multi-step speed control
P10.02
Multi-step
speed 0
The frequency setting range of stage 0~15:
-100.0~100.0%, 100.0% of the frequency setting
corresponds to the Max. frequency P00.03.
If multi-step speed operation is selected, multi-step
speeds are in the range of -f
max
~f
max
and it can be set
continuously. The start-up and stop during multi-step
speed is decided by P00.01.
Goodrive300-19 series inverters can set 16 stages
speed, selected by the combination of multi-step
terminals 1~4 (select the setting by S terminals, the
corresponding function codes are P05.01~P05.09),
corresponding to the speed 0 to speed 15.
0.0%
○
P10.04
Multi-step
speed 1
0.0%
○
P10.06
Multi-step
speed 2
0.0%
○
P10.08
Multi-step
speed 3
0.0%
○
P10.10
Multi-step
speed 4
0.0%
○
P10.12
Multi-step
speed 5
0.0%
○
P10.14
Multi-step
speed 6
0.0%
○
P10.16
Multi-step
speed 7
0.0%
○
P10.18
Multi-step
speed 8
0.0%
○
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...