Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-79-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
37: Motor 2 in operation
38~40: Reserved
P06.05
Polarity of
output
terminals
The function code is used to set the pole of the output
terminal.
When the current bit is set to 0, input terminal is
positive.
When the current bit is set to 1, input terminal is
negative.
BIT3
BIT2
BIT1
BIT0
RO2
RO1
HDO
Y
Setting range: 00~0F
00
○
P06.06
Y switch-on
delay time
The function code defines the corresponding delay
time of the electrical level change during the
programmable terminal switching on and off.
The setting range: 0.000~50.000s
Note: P06.08 and P06.08 are valid only when
P06.00=1.
0.000s
○
P06.07
Y switch-off
delay time
0.000s
○
P06.08
HDO
switch-on
delay time
0.000s
○
P06.09
HDO
switch-off
delay time
0.000s
○
P06.10
RO1
switch-on
delay time
0.000s
○
P06.11
RO1
switch-off
delay time
0.000s
○
P06.12
RO2
switch-on
delay time
0.000s
○
P06.13
RO2
switch-off
delay time
0.000s
○
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...