Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-93-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
ratio of
dropping
control
several inverters drive one load.
Setting range: 0.00~50.00Hz
P08.31
Motor
shifting
Goodrive300-19 series supports the shift between
two motors. This function is used to select the shifting
channel.
0x00~0x14
LED ones: shifting channel
0: terminal shifting; digital terminal is 35
1: Modbus communication shifting
2~4: Reserved
LED tens: shifting enabling in operation
0: Disabled
1: Enabled
0x00
◎
P08.32
FDT1
electrical
level
detection
value
When the output frequency exceeds the
corresponding frequency of FDT electrical level, the
multi-function digital output terminals will output the
signal of
“frequency level detect FDT” until the output
frequency decreases to a value lower than (FDT
electrical level
—FDT retention detection value) the
corresponding frequency, the signal is invalid. Below
is the waveform diagram:
Setting range of P08.32: 0.00Hz~P00.03 (the Max.
frequency)
50.00Hz
○
P08.33
FDT1
retention
detection
value
5.0%
○
P08.34
FDT2
electrical
level
detection
value
50.00Hz
○
P08.35
FDT2
retention
detection
value
5.0%
○
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...