Goodrive300-19 series open loop vector inverter special for hosit Quick start-up
-9-
Quick start-up
2
2.1 What this chapter contains
This chapter mainly describes the basic guidelines during the installation and commission procedures
on the inverter, which you may follow to install and commission the inverter quickly.
2.2 Unpacking inspection
Check as followings after receiving products:
1. Check that there are no damage and humidification to the package. If not, please contact with
local agents or company offices.
2. Check the information on the type designation label on the outside of the package to verify
that the drive is the correct type. If not, please contact with local dealers or company offices.
3. Check that there are no signs of water in the package and no signs of damage or breach to
the inverter. If not, please contact with local dealers or company offices.
4. Check the information on the type designation label on the outside of the package to verify
that the name plate is the correct type. If not, please contact with local dealers or company
offices.
5. Check to ensure the accessories (including
user’s manual, control keypad and extension
card) inside the device are complete. If not, please contact with local dealers or company
offices.
2.3 Application confirmation
Check the machine before beginning to use the inverter:
1. Check the load type to verify that there is no overload of the inverter during work and check
that whether the drive needs to modify the power degree.
2. Check that the actual current of the motor is less than the rated current of the inverter.
3. Check that the control accuracy of the load is the same of the inverter.
4. Check that the grid voltage is consistent with the rated voltage of the inverter.
5. Check that the communication needs optional card or not.
2.4 Environment
Check as followings before the actual installation and usage:
1. Check that the ambient temperature of the inverter is below 40°C. If exceeds, derate 1% for
every additional 1°C. Additionally, the inverter can not be used if the ambient temperature is
above 50°C.
Note: for the cabinet inverter, the ambient temperature means the air temperature inside
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...