Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-180-
7.15 Hierarchical multi-step speed running
Hierarchical multi-step speed reference is a speed reference mode specially designed according to
the applications of hoists. The mode can realize at most 6 steps hierarchical speed selection through
the combinations of 5 hierarchical speed reference terminals, as shown below:
Hierarchical
reference
terminal 1
Hierarchical
reference
terminal 2
Hierarchical
reference
terminal 3
Hierarchical
reference
terminal 4
Hierarchical
reference
terminal 5
Speed
setting
Function
code
OFF
OFF
OFF
OFF
OFF
Hierarchical
reference 0
P19.06
ON
OFF
OFF
OFF
OFF
Hierarchical
reference 1
P19.07
ON
ON
OFF
OFF
OFF
Hierarchical
reference 2
P19.08
ON
ON
ON
OFF
OFF
Hierarchical
reference 3
P19.09
ON
ON
ON
ON
OFF
Hierarchical
reference 4
P19.10
ON
ON
ON
ON
ON
Hierarchical
reference 5
P19.11
Note: Only when all lower hierarchical references close can the upper hierarchical references
close. Generally, set hierarchical reference 0 to 0.0%.
Set speed reference to hierarchical multi-step speed reference mode (P00.06=13 or P00.07=13). The
hierarchical terminal reference is determined by the combinations of 61-65 in P5 group and the speed
is set by P19.06~P19.11 (the percentage of P00.03).
Function
code
Name
Detailed instruction of parameters
Default
value
P00.06
A frequency command
13: Hierarchical multi-step speed
reference
0
P00.07
B frequency command
2
P05.00
HDI input selection
0: High-speed pulse input
1: Digital input
0
P05.01
S1 terminal function selection 61: Hierarchical reference terminal 1
62: Hierarchical reference terminal 2
63: Hierarchical reference terminal 3
64: Hierarchical reference terminal 4
65: Hierarchical reference terminal 5
1
P05.02
S2 terminal function selection
2
P05.03
S3 terminal function selection
7
P05.04
S4 terminal function selection
0
P05.05
S5 terminal function selection
0
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...