background image

7   SETUP/MAINTENANCE

Invacare® Formula™ CG Seating

92

Part No 1143155

7.15 About Batteries

This section contains information on batteries used on the TDX SP and TDX SR with elevate or TDX SP vent tray option or the FDX with vent tray 

option. For batteries on other wheelchairs equipped with a Formula CG powered seating system refer to base owner’s manual shipped with 

wheelchair.

Have the following tools available: 

TOOL

QTY

COMMENTS

Battery Lifting Strap

1

Supplied

1/2-inch (6 pt) Box Wrench

1

Not Supplied

7/16-inch (6pt) Box Wrench

1

Not Supplied

3/8-inch (6pt) Box Wrench

1

Not Supplied

Diagonal Cutters

1

Not Supplied

Содержание Formula CG Seating

Страница 1: ...EN This manual MUST be given to the user of the product BEFORE using this product read this manual and save for future reference Invacare Formula CG Seating Power Wheelchair Seat Tilt Recline Elevate...

Страница 2: ...ights reserved Republication duplication or modification in whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by o...

Страница 3: ...raints Trro or TRBKTS 15 Powered Seating 16 Repair or Service Information 17 Safety Handling 18 Pinch Points 19 Stability and Balance 20 Footplates and Front Rigging 20 Reaching Leaning and Bending Fo...

Страница 4: ...ng the Single Function Switch 32 Using the MK6i SPJ w ACC Joystick 32 Using the Four Way Toggle 33 Using the CMPJ Joystick 34 Operating the Wheelchair 37 Turning the Power On Off 37 Using the Joystick...

Страница 5: ...ings 52 Installing Removing Footrests 52 PH904A PHAL4A 70 and PW93 52 70 Taper 53 Raising Lowering Elevating Front Riggings 53 Installing Removing Elevating Legrests 54 Installing 54 Removing 54 Raisi...

Страница 6: ...ip Up Footplates 66 Depth Adjustment 66 Angle Adjustment 67 Perpendicular and or Inversion Eversion Adjustment 67 Adjusting the Height of the Manual Center Mount Footrest 68 Adjusting the Angle of the...

Страница 7: ...s 83 Composite Articulating Footplate Heel Loop Replacement 84 Disassembly 84 Assembly 84 Repositioning Joystick 85 Disconnecting Connecting the Joysticks 86 SPJ Joysticks 86 CMPJ Joysticks 87 Replaci...

Страница 8: ...00 Connecting Disconnecting the Battery Wiring Harness TDX SP and TDX SR with Elevating Seat Only 102 Using the Proper Batteries 103 Battery Wiring Harness TDX SP and TDX SR with Elevating Seat Only 1...

Страница 9: ...hazardous situation which if not avoided will result in death or serious injury WARNING Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injur...

Страница 10: ...Documents Refer to the table below for part numbers of additional documents which are referenced in this manual WARNING Refer to wheelchair base owner s manual for additional safety and operation inf...

Страница 11: ...repair and or replacement For warranty service please contact the dealer from whom you purchased your Invacare product In the event you DO NOT receive satisfactory warranty service please write direc...

Страница 12: ...n the event you DO NOT receive satisfactory warranty service please write directly to Invacare at the address on the bottom of the back cover Provide dealer s name address date of purchase indicate na...

Страница 13: ...gned and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare produc...

Страница 14: ...ause injury to the driver bystanders damage to the wheelchair and to surrounding property After the wheelchair has been set up adjusted check to make sure that the wheelchair performs to the specifica...

Страница 15: ...TRBKTS includes four factory installed wheelchair transport brackets TRBKTS has not been crash tested in accordance with WC 19 Use these transport brackets only to secure an unoccupied wheelchair duri...

Страница 16: ...rate the wheelchair or elevate lower the seat DO NOT attempt to adjust the drive lock out Have the wheelchair serviced by a qualified technician Use only the controls listed in Operating Powered Seati...

Страница 17: ...re frequently exposed to water may require replacement of electrical components more frequently DO NOT overtighten hardware attaching to the frame This could cause damage to the frame tubing Transport...

Страница 18: ...bending reaching and transferring activities in the presence of a qualified healthcare professional before attempting active use of the wheelchair Always shift your weight in the direction you are tu...

Страница 19: ...when the seat is in the lowest seat to floor height Pinch point may occur when returning the tilted seat to the full upright position Make sure the hands and body of the occupant attendants and bystan...

Страница 20: ...s sloping surfaces in the presence of a qualified healthcare provider before attempting active use of this wheelchair Other general warnings listed within this document also apply WARNING DO NOT use t...

Страница 21: ...roperty may result DO NOT use if the joystick boot is torn or cracked If the joystick boot becomes torn or cracked replace IMMEDIATELY WARNING Invacare DOES NOT recommend the use of its wheelchairs as...

Страница 22: ...elatively intense electromagnetic fields in the everyday environment Some of these sources are obvious and easy to avoid Others are not apparent and exposure is unavoidable However we believe that by...

Страница 23: ...te hand held transceivers transmitters receivers such as citizens band CB radios or turn ON personal communication devices such as cellular phones while the powered wheelchair is turned ON 2 Be aware...

Страница 24: ...e for additional label located on the wheelchair base Refer to Service Manual to reposition the seat otherwise serious personal injury and damage will result WARNING P N 1114823 Rev B 5 10 06 Weight C...

Страница 25: ...3 LABEL LOCATIONS Part No 1143155 25 Invacare Formula CG Seating 3 2 TDX SP with Vent Tray Option...

Страница 26: ...4 inches 16 to 24 inches 16 to 22 inches 16 to 24 inches TDX SP SR Only 16 to 22 inches All other wheelchairs 16 to 24 inches TDX SP SR Only 16 to 22 inches All other wheelchairs Seat Depth Range 1 in...

Страница 27: ...ments 16 to 26 inches in 1 inch increments Back Angle Range Tilt or Elevate 85 to 105 in 5 increments Tilt Range 300 lbs Tilt Tilt Recline Tilt Recline Elevate 400 lbs Tilt Tilt Recline 0 to 55 0 to 4...

Страница 28: ...w has a 275 lb weight limitation FORMULA CG Seat Weight Tilt Only Tilt Recline 93 lbs 113 lbs Weight Limitation Without Heavy Duty Option With Heavy Duty Option With Vent Tray Up to 300 lbs Up to 400...

Страница 29: ...and before use make sure that all attaching hardware is tightened securely otherwise injury or damage may result Set up of the Electronic Control Unit is to be performed only by a qualified technician...

Страница 30: ...n over 20 relative to the vertical position If the drive lock out does not stop the wheelchair from operating or the seat from elevating lowering in a tilt recline back angle position over 20 relative...

Страница 31: ...g in a tilted reclined or elevated position DO NOT operate the seating system while on an incline DO NOT operate seating system while the wheelchair is moving DO NOT operate the tilt function near or...

Страница 32: ...tilt mode 3 Move the joystick SYSTEM TYPE JOYSTICK POWERED SEATING CONTROL 4 POLE MOTOR SWITCH OPTION THROUGH THE JOYSTICK TTJ Single Actuator Tilt Only Recline Only or Elevate Only MK6i SPJ w PSS Sin...

Страница 33: ...OFF OFF Formula CG Recline w Legs Decrease the Recline Angle Increase the Recline Angle Power Legrest Up Power Legrest Down Formula CG Tilt Recline Decrease the Tilt Angle Legs Down Increase the Tilt...

Страница 34: ...surface 2 Select a drive that has the Actuator Control Switch Mode icon displayed 3 Select the Actuator Control Switch Mode icon Detail A 4 Four of the following icons will display when Actuator Cont...

Страница 35: ...r Mount Leg Elevate Operations Right Leg Operations Left Leg Operations Recline with Leg Operations No Icons No powered seating operation has been programmed for this quadrant The three icons indicate...

Страница 36: ...B ACTUATOR CONTROL SWITCH MODE EXAMPLE SCREEN DETAIL A SELECTING THE ACTUATOR CONTROL SWITCH MODE DETAIL C EXAMPLE SCREEN DURING POWERED SEATING OPERATION Mode Icons Actuator Control Switch Mode Icon...

Страница 37: ...r Off can be achieved by performing one of the following steps FIGURE 4 Turning the Power On Off For this procedure refer to FIGURE 4 JOYSTICK ACTION CMPJ Move the On Off switch Forward to the On posi...

Страница 38: ...he wheelchair moves The maximum speed however is limited by the setting of the speed control knob To slow the wheelchair to a stop simply release the joystick The wheelchair has automatic speed and di...

Страница 39: ...e front of the wheelchair REVERSE Pull joystick back towards the rear of the wheelchair Turn RIGHT Move joystick toward the right side of the wheelchair Turn LEFT Move joystick toward the left side of...

Страница 40: ...C Joystick Switches and Indicators For this procedure refer to FIGURE 6 On Off Button Charger Programming Input Speedometer Joystick GREEN LED Information Gauge Display Service Indicator Decrease Spee...

Страница 41: ...ttons tortoise button and hare button are used to set and adjust the maximum speed 1 To adjust the speed perform one of the following Adjust Speed in 20 Increments 5 Speed Mode Press the tortoise butt...

Страница 42: ...front of the joystick housing and provides the following information to the user on the status of the wheelchair 1 Power is On 2 True state of battery charge including notification of when the batter...

Страница 43: ...1 can be programmed for higher speeds and quicker response while DRIVE 2 can be programmed for slower speeds and less responsiveness or vise versa The other two drive programs could be indoor and outd...

Страница 44: ...automatic speed and direction compensation to minimize corrections Charger Programming Input The charger programming input is located at the front of the joystick housing This provides easy access for...

Страница 45: ...f the LCD display is the Information Center The Information Center displays current data on the wheelchair Refer to LCD Display table on page 45 for descriptions of information shown LCD DISPLAY For t...

Страница 46: ...erride switch is active MODES The dotted box shows the area that contains the available modes in the currently selected drive The modes are programmed for each drive and are based upon the configurati...

Страница 47: ...e main screen was highlighted FIGURE 10 LCD Display Screens Driving Screen Available Modes in this Drive Must be Programmed Top Highlighted Icon Indicates Selected Mode Clock Battery Gauge Display Sta...

Страница 48: ...hange the highlighted value hour minute AM PM month day year Move the joystick Right or Left to select a value or the Set icon Highlight the Set icon and move the joystick forward to enter new date an...

Страница 49: ...tor Elevate Actuator Generic Tilt Actuator Generic Recline Actuator Connected Devices Screen ICON DESCRIPTION Generic Leg Actuators Generic Right Leg Actuator Generic Left Leg Actuator Intelligent CG...

Страница 50: ...ion through mono port 2 Remote Stop Switch The remote reset switch may be used to stop the wheelchair if the wheelchair is in motion The remote reset switch also functions in the same way as the joyst...

Страница 51: ...ower up Running Lights ON Off If any of the above modes are selected the control will require activation of the switch immediately after the power switch is turned On in order to enter the drive mode...

Страница 52: ...the wheelchair is moving minimum ground clearance for the front rigging is three inches If the wheelchair is not moving the front rigging MUST maintain a minimum of one inch ground clearance otherwis...

Страница 53: ...djust footrest height if desired Refer to Footrest Height Adjustment on page 63 FIGURE 13 Installing Removing Footrests 70 Taper 5 9 Raising Lowering Elevating Front Riggings 1 Perform one of the foll...

Страница 54: ...chair adjust footplate to correct height by loosening nut and sliding the lower footrest assembly UP or down until desired height is achieved Removing 1 Push the legrest release handle toward the insi...

Страница 55: ...Turn the calfpad towards the outside of the wheelchair 2 Slide the calfpad UP or down until the desired position is obtained 3 Turn the calfpad towards the inside of the wheelchair FIGURE 16 Raising...

Страница 56: ...t footrest out of the mounting bracket of the seat frame Installing 1 Engage the release lever with one hand hold the center mount footrest with the other and insert the center mount footrest into the...

Страница 57: ...t personal injury always verify proper positioning of legs and feet prior to use Individual user weight may impact the rate of travel for each legrest assembly If simultaneous operation is desired sel...

Страница 58: ...grest release handle and swing legrest to the outside of the wheelchair 3 Lift up on powered legrest and remove from wheelchair 4 Repeat STEPS 1 3 for opposite power legrest FIGURE 18 Installing Remov...

Страница 59: ...positioning the flip back armrest release lever into the up horizontal position 2 Remove the quick release pin that secures the flip back armrest to the rear arm socket 3 Pull UP on the flip back arm...

Страница 60: ...essing flip back armrest release lever into the down vertical position 4 Lift up on flip back armrest to make sure the armrest is locked in place 5 Repeat STEPS 1 4 for opposite flip back armrest if n...

Страница 61: ...ng Cantilever Arms 1 Pull the end of the cantilever arm down to lower the cantilever arm 2 Pull the end of the cantilever arm up to move it out of the way FIGURE 21 Using Non Locking Cantilever Arms W...

Страница 62: ...er Operation WARNING NEVER operate the wheelchair while in any recline position over 105 relative to the seat frame If the limit switch does not stop the wheelchair from operating in a recline positio...

Страница 63: ...ware is tightened securely otherwise injury or damage may result While the wheelchair is moving minimum ground clearance for the front rigging is three inches If the wheelchair is not moving the front...

Страница 64: ...footrest to the desired height 5 Reinstall the mounting screw washers and locknut that secure the lower footrest to the footrest support and tighten securely 6 Repeat STEPS 1 5 for the opposite wheel...

Страница 65: ...re lower footrest assembly with existing mounting screw and coved spacer Securely tighten 6 Reinstall the footrest s onto the wheelchair Refer to Installing Removing Footrests on page 52 7 Reinstall a...

Страница 66: ...lat screws washers and locknuts FIGURE 4 Adjusting Adjustable Angle Flip Up Footplates For this procedure refer to FIGURE 4 Observe the angle of the footplate for reinstallation The settings for posit...

Страница 67: ...wly turn nylon adjustment screw in or out until footplate is perpendicular to the footrest assembly or the desired inversion or eversion is obtained FIGURE 6 FIGURE 6 Perpendicular and or Inversion Ev...

Страница 68: ...hile the wheelchair is moving minimum ground clearance for the front rigging is three inches If the wheelchair is not moving the front rigging MUST maintain a minimum of one inch ground clearance othe...

Страница 69: ...earance for the front rigging is three inches If the wheelchair is not moving the front rigging MUST maintain a minimum of one inch ground clearance otherwise personal injury and damage may result PIN...

Страница 70: ...tplate Angle 1 Flip footplate up 2 Screw the adjustment screw in or out until the desired angle is achieved 3 Repeat STEPS 1 and 2 for the other footplate FIGURE 9 Adjusting the Footplate Angle Manual...

Страница 71: ...ever Arm 1 Adjust the cantilever arm angle as necessary to accommodate the user To adjust the arm angle down turn the adjustment screw clockwise To adjust the arm angle up turn the adjustment screw co...

Страница 72: ...ng the cane brackets to the back canes 3 Align the upper mounting holes in the back canes with the desired mounting holes in the cane brackets Detail A 4 Install the two upper hex screws washers and l...

Страница 73: ...Upholstery 1 Rotate the spreader bar either Counterclockwise away from back upholstery to loosen back headrest upholstery Clockwise towards back upholstery to tighten back headrest upholstery FIGURE...

Страница 74: ...at cables do NOT become entangled and damaged during normal operation of seating system Ensure proper operation of powered functions Example seating and legrests Setup delivery inspection should be pe...

Страница 75: ...alified technician for a thorough inspection and servicing Service Inspection on page 77 Weekly monthly and periodic inspections should be performed by user attendant between the six month service ins...

Страница 76: ...sh against arm tube Inspect foam handgrips for damage If damaged have them replaced by a qualified technician Check center mount front riggings for loose fasteners Replace tighten if necessary Check t...

Страница 77: ...ap for any signs of wear Ensure buckle latches Verify hardware that attaches strap to frame is secure and undamaged Replace if necessary Check center mount front riggings for loose fasteners Replace t...

Страница 78: ...Check power center mount front riggings for worn frayed belts and or loose fasteners If found replace these items Make sure all electrical connections are secure Make sure drive lock out operates prop...

Страница 79: ...emove the lower footrest 4 Remove the phillips bolt spacer and locknut that secure the existing heel loop to the lower footrest 5 Slide the existing heel loop off the lower footrest 6 Replace heel loo...

Страница 80: ...e side rail 2 Remove existing telescoping front rigging 3 Perform one of the following Reclining Seating Systems Only Refer to Detail A in FIGURE 2 to determine the mounting position for the new teles...

Страница 81: ...scoping Front Rigging Support Telescoping Front Tube Cap Screws Spacers Threaded Blocks Cap Screws Spacers Side Rail Side Rail DETAIL A MOUNTING POSITIONS FOR RECLINING SEATING SYSTEMS 22 inch Seat De...

Страница 82: ...otplate hinge remains in the up position 5 Check the up and down motion of the footplate hinge to make sure the user of the wheelchair can operate the footplates easily 6 Adjust footplate Refer to Ins...

Страница 83: ...two flat screws that secure the footplate to the half clamp 3 Adjust the footplates to the necessary angle and depth for the user Refer to Adjusting Adjustable Angle Flip Up Footplates on page 66 FIGU...

Страница 84: ...heel loop to the footrest 4 Slide heel strap over cane of footrest assembly Articulating 1 Remove the two mounting screws that secure the heel loop to the articulating footplate Assembly 1 Replace hee...

Страница 85: ...et is on the inside of the arm tube as shown in FIGURE 6 5 Using the three hex mounting screws and washers secure both halves of the mounting bracket to the arm tube 6 Slide the joystick mounting tube...

Страница 86: ...GREY collar portion of the joystick connector with one hand and the controller connector on the wheelchair in the other and align them 2 Lightly push to engage the joystick connector and the controll...

Страница 87: ...ctor to the other connectors 3 Top and Bottom Connectors Install connector caps onto the network connector 4 Push the latch in to secure the network connectors and caps 5 If necessary secure excess ca...

Страница 88: ...p inside of the seat frame as shown 6 Reinstall the two mounting screws and quick release pin tabs that secure the seat positioning straps to the seat frame and torque to 75 in lbs 7 Reinstall the sea...

Страница 89: ...djusting Headrest Height 1 Loosen the set screw on the headrest stop 2 Loosen but DO NOT remove the thumb screw that secures the headrest to the headrest mounting bracket 3 Position the headrest to th...

Страница 90: ...ely tighten the three socket screws 5 If necessary adjust the height of the headrest Refer to Adjusting Headrest Height on page 89 7 13 Replacing Headrest 1 Remove the three socket screws that secure...

Страница 91: ...fer to Adjusting Back or Headrest Upholstery on page 73 Replacing Headrest Upholstery 1 Remove the six mounting screws that secure the headrest upholstery to the headrest extensions 2 Remove the exist...

Страница 92: ...r the FDX with vent tray option For batteries on other wheelchairs equipped with a Formula CG powered seating system refer to base owner s manual shipped with wheelchair Have the following tools avail...

Страница 93: ...on page 97 3 Verify the joystick On Off switch is in the Off position and disconnect joystick Refer to Disconnecting Connecting the Joysticks on page 86 4 Remove the rear front and top shrouds Refer...

Страница 94: ...ition actuator lead and drive limit switch lead under the rear battery handle 5 Connect the following The battery wiring harness to the battery controller connector The drive limit switch to the magne...

Страница 95: ...ling Removing the Batteries TDX SP and TDX SR with Elevating Seat Battery Strap Front Battery Lead Rear Battery Lead Battery Box Actuator Controller Connector Battery Wiring Harness Drive Limit Switch...

Страница 96: ...elevate actuator connector The elevator actuator is marked with a tag reading Elevate The power bypass connection requires 12 to 24 Volts DC to operate the actuator This bypass is intended for use by...

Страница 97: ...st and set aside Installing 1 Position the seat assembly onto the actuator post 2 Using four mounting bolts and locknuts secure the seat assembly to the actuator post Securely tighten 3 Position the s...

Страница 98: ...ud and battery retention bracket Refer to Removing Installing the Wheelchair Shrouds TDX SP SR on page 100 4 Disconnect the wiring harness from the controller connector 5 Disconnect the front battery...

Страница 99: ...the ventilator connector 7 Install the rear shroud front shroud and battery retention bracket Refer to Removing Installing the Wheelchair Shrouds TDX SP SR on page 100 8 Connect the joystick Refer to...

Страница 100: ...retention bracket from the base frame and remove the front shroud battery retention bracket from the base frame Top Shroud 1 Remove the seat from the base frame 2 Remove the four pan head screws secu...

Страница 101: ...ula CG Seating FIGURE 16 Removing Installing the Wheelchair Shrouds TDX SP SR Front Shroud Battery Retention Bracket Base Frame Socket Head Screws Top Shroud Rear Shroud Pan Head Screws Front Shroud B...

Страница 102: ...ur and serious personal injury or damage may occur When tightening the clamps ALWAYS use a box wrench Pliers will round off the nuts NEVER wiggle the battery terminal s post s when tightening The batt...

Страница 103: ...e the POSITIVE battery terminal WARNING FOR TDX SP AND TDX SR WHEELCHAIRS USE 22NF BATTERIES Batteries with terminal configuration POSITIVE on the left and NEGATIVE on the right as shown below MUST be...

Страница 104: ...Secure the NEGATIVE battery cable to the NEGATIVE battery post with existing mounting screw and locknut 10 Secure the bracket of the POSITIVE battery cable to the POSITIVE battery post with existing...

Страница 105: ...Connector Bracket POSITIVE Battery Terminal Post Mounting Screw 22NF Battery NEGATIVE Battery Cable NEGATIVE Battery Terminal Post Locknut Battery Wiring Harness FOR FRONT BATTERY FOR REAR BATTERY Br...

Страница 106: ...ition battery connector bracket or wiring harness onto the new 22NF battery as shown 9 Secure the NEGATIVE battery cable to the NEGATIVE battery post with existing mounting screw and locknut 10 Secure...

Страница 107: ...st Locknut LEFT WHEELCHAIR BATTERY WIRING HARNESS VENT WIRING HARNESS Bracket of POSITIVE Battery Cable NEGATIVE Battery Cable POSITIVE Battery Terminal Posts NEGATIVE Battery Terminal Post LEFT WHEEL...

Страница 108: ...batteries by the hook and loop battery strap The hook and loop battery strap should be used to assist in removing the batteries form the wheelchair base frame DO NOT tip the battery Keep the battery...

Страница 109: ...ntion bracket from the wheelchair base frame 7 Disconnect the vent battery connector from the vent battery cable connector 8 Remove the vent battery from the wheelchair base frame 9 If necessary remov...

Страница 110: ...e of the battery DO NOT tip the batteries Keep the batteries in an upright position NEVER allow any of your tools and or battery cable s to contact BOTH battery post s at the same time An electrical s...

Страница 111: ...inspect the battery to ensure the correct position of the POSITIVE and NEGATIVE terminals FIGURE 20 Using the Proper Batteries For this procedure refer to FIGURE 20 WARNING Batteries with terminal co...

Страница 112: ...f the battery 7 Reverse STEPS 3 6 to connect the vent battery wiring harness to the vent battery FIGURE 21 Disconnecting Connecting the Vent Battery Wiring Harness FDX with Vent Tray Option For this p...

Страница 113: ...ttery terminals DO NOT remove fuse or mounting hardware from POSITIVE RED battery cable mounting screw CAUTION ALWAYS disconnect the ventilator battery harness from the ventilator battery harness exte...

Страница 114: ...22NF batteries are installed and that the front 22NF battery wiring harness is connected to the ventilator battery harness connector Refer to Installing Removing the Batteries TDX SP with Vent Tray Op...

Страница 115: ...r reclined beyond drive lock out angle 20 Motor lock levers are disengaged Return to neutral position upright and completely lowered Refer to Operating Powered Seating Systems on page 31 Contact Invac...

Страница 116: ...are found only the first error encountered by the control module will be displayed Information Gauge Display Diagnostics DISPLAY DESCRIPTION DEFINITION COMMENTS All LEDs are off Power is off All LEDs...

Страница 117: ...e connected properly If necessary replace batteries Refer to the wheelchair base owner s manual 3 Left Motor Fault Contact Invacare Dealer for service 4 Right Motor Fault Contact Invacare Dealer for s...

Страница 118: ...T displays and wheelchair does not drive Motor lock levers disengaged Error code E9 or E10 Engage motor lock levers Refer to owner s manual shiped with wheelchair CHARGER PLUGGED IN displays Battery c...

Страница 119: ...ule is not communicating with the control module Error code E200 Check the connections between the joystick or display and the controller Turn the power off and then back on Replace the controller if...

Страница 120: ...teries if necessary Refer to Replacing the Batteries and or Battery Cables on page 83 Motor chatters or runs irregular Motor gearbox malfunction Stop use of Wheelchair Contact Dealer Invacare for Serv...

Страница 121: ...NOTES Part No 1143155 121 Invacare Formula CG Seating Notes...

Страница 122: ...NOTES Invacare Formula CG Seating 122 Part No 1143155 Notes...

Страница 123: ...NOTES Part No 1143155 123 Invacare Formula CG Seating Notes...

Страница 124: ...care Corporation USA One Invacare Way Elyria Ohio USA 44036 2125 800 333 6900 Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800 668 5324 Part No 1143155 Rev O 04 11 www invacare...

Отзывы: