6 ADJUSTMENT
Part No 1143155
65
Invacare® Formula™ CG Seating
70° Taper
1.
Remove any accessory from the footrest(s).
2.
Remove the footrest from the wheelchair. Refer to Installing/Removing Footrests on page 52
.
3.
Remove the mounting screw and coved spacer that secures the
lower footrest assembly.
4.
Position the footrest assembly to the desired height.
5.
Secure lower footrest assembly with existing mounting screw and
coved spacer. Securely tighten.
6.
Reinstall the footrest(s) onto the wheelchair. Refer to Installing/
Removing Footrests on page 52.
7.
Reinstall any accessory onto the footrest(s).
FIGURE
3
Footrest Height Adjustment - 70° Taper
Lay the assembly on a flat surface to improve access to the hardware.
Note the position of the spacers before disassembly.
Make sure spacers are positioned properly when
reassembling to prevent damage to the frame
mounting tubes.
Coved Spacer
Mounting Screw
Heel Loop
Footrest