nugget
Using the Default Applications
C-5
C
•
On the 246X terminal, you can select character sets by using the DX configuration
command or the ANSI escape sequence (ESC[dataw). For help, see “Selecting
Character Sets” later in this appendix.
Using Display Control Codes
You can use control codes to position the cursor or to format the terminal display. The
EM9560.BIN
application recognizes the display control codes listed next.
Command
Control Code
Description or Action
Backspace
BS (08 Hex)
Moves the cursor one position to the left until
the cursor reaches the first column. If the
cursor is in the first column of any row except
the first row, a Backspace command moves the
cursor to the last column of the previous row.
Cursor Position
ESC[
n
;
v
H
Moves the cursor to the position specified by
the n and v parameters where:
n
specifies the row or line number.
v
specifies the column number.
If you enter zero or no parameter, n and v are
set to one. If n or v exceeds the maximum row
or column number on the display, the
parameters are set to the screen’s maximum.
Erase Display
ESC[2J
Erases the entire display and returns the cursor
to the home position (row 1, column 1). This
command also erases the entire virtual display
image (buffer with up to two rows of the most
recently displayed data).
Home
CR (0D Hex)
Returns the cursor to the first column of the
current row.
Next Line
LF (0A Hex)
Moves the cursor down one row in the current
column position. If the cursor is already in the
last row, a new line is added.
Restore Configured
Character Set
ESC[x
Returns the display to the character set that is
defined in the default configuration.
Restore Cursor
Position
ESC[u
Restores the cursor position saved with a Save
Cursor Position command. Each Restore
Cursor Position command must be paired with
a preceding Save Cursor Position command. If
a Save Cursor Position command has not been
previously entered, the cursor position will not
change.
Содержание Trakker Antares 2460
Страница 1: ...Trakker Antares 246X Stationary Terminal User s Manual...
Страница 4: ...blank page...
Страница 19: ...Introducing the 246X Stationary Terminal 1...
Страница 20: ...blank page...
Страница 29: ...Installing the Terminal 2...
Страница 30: ...blank page...
Страница 47: ...Configuring the Terminal 3...
Страница 48: ...blank page...
Страница 58: ...blank page...
Страница 59: ...Operating the Terminal in a Network 4...
Страница 60: ...blank page...
Страница 88: ...blank page...
Страница 89: ...Programming the Terminal 5...
Страница 90: ...blank page...
Страница 107: ...Troubleshooting 6...
Страница 108: ...blank page...
Страница 121: ...Reader Command Reference 7...
Страница 122: ...blank page...
Страница 149: ...Configuration Command Reference 8...
Страница 150: ...blank page blank page...
Страница 242: ...blank page blank page...
Страница 243: ...Specifications A...
Страница 244: ...blank page blank page...
Страница 257: ...Full ASCII Charts B...
Страница 258: ...blank page blank page...
Страница 267: ...Using the Default Applications C...
Страница 268: ...blank page blank page...
Страница 279: ...Index I...
Страница 280: ...blank page...
Страница 290: ...body text 4...