background image

Ver. 3.003  

p91

CONCEPT IQ. PLUS  Programmer’s Manual.

570 to 589

Holidays ................................................................................................ 54

571

Holiday Month ....................................................................................... 55

590 to 595

Daylight Saving .................................................................................... 55

590 to 595

Daylight Saving Programming - Basic ................................................ 22

590 to 595

Daylight Saving Time (DST) Start And End Dates ............................. 55

600

End-of-line Resistor Type .................................................................... 56

600 to 666

Zone Input Programming - Basic                                                       19-20

600 to 666

Zone Input Programming - Basic ........................................................ 23

601 to 616

24 Hour Zone Types ............................................................................ 58

601 to 616

Delayed Zone Type .............................................................................. 57

601 to 616

Duress Zone Type ................................................................................ 58

601 to 616

Fire Zone Type ..................................................................................... 58

601 to 616

Handover Zone Type ........................................................................... 57

601 to 616

Home Zone Types ................................................................................ 57

601 to 616

Instant Zone Type ................................................................................. 57

601 to 616

Key Switch Zone Types ....................................................................... 58

601 to 616

Panic Zone Type .................................................................................. 58

601 to 616

Zone Type ............................................................................................. 57

601 to 616

Zone Input Programming Overview .................................................... 56

651 to 666

Day Alarm Zone Option ....................................................................... 60

651 to 666

Dialer Lockout Zone Option ................................................................. 59

651 to 666

Normally Open (Change Sense) Zone Option ................................... 60

651 to 666

Pulse Count Zone Option .................................................................... 59

651 to 666

Self-Test Zone Option .......................................................................... 60

651 to 666

Silent Zone Option ............................................................................... 59

651 to 666

Siren Lockout Zone Option .................................................................. 59

651 to 666

Zone Options ........................................................................................ 60

701 to 716

Zone Areas ........................................................................................... 60

750 to 769

Timezones ............................................................................................ 61

800 to 810

Auxiliary Event Type ............................................................................. 62

800 to 810

Auxiliary Event Types ........................................................................... 62

800 to 870

Auxiliary Programming Overview ........................................................ 62

801

Strobe Programming - Basic ............................................................... 22

830 to 840

Auxiliary Timer Value ........................................................................... 63

860 to 870

Auxiliary Action ..................................................................................... 63

860 to 870

Auxiliary Actions ................................................................................... 78

890

Auto Isolate on Arming ......................................................................... 64

890

Clock synchronized to 50Hz AC Mains. .............................................. 64

890

Display Zone activity on Terminals. ..................................................... 64

890

Force Arm Areas. ................................................................................. 64

890

General Option Programming - Basic ................................................. 21

890

General Options.  1. ............................................................................. 64

890

Quick Arming ........................................................................................ 64

890

Single Exit Beep in Home Mode. ........................................................ 64

890

Special Siren Tone for System Alarms. ............................................... 64

890

Zone activity on Terminals.  To Display. .............................................. 64

890

Zone Alarm indication after Disarm. .................................................... 64

891

All Area Siren Off control. .................................................................... 65

891

Bell Squawk on Siren for Wireless Remote Key. ............................... 65

891

Call Forwarding. ................................................................................... 65

891

Day Alarms To Activate Terminal Beeper ............................................ 65

891

Delay Siren until Comms complete ..................................................... 65

891

Dialer enabled in Home Mode. ............................................................ 65

891

DTMF Control. ...................................................................................... 65

891

General Options.  2. ............................................................................. 65

891

Multi-Area System. ............................................................................... 65

891

Mutli-Area Option Programming - Basic ............................................. 23

891

Terminal Beeper for Day Alarms. ........................................................ 65

892

6 Digit PIN codes ................................................................................. 66

892

Automatic Battery Testing. ................................................................... 66

892

Battery Test on Arming. ........................................................................ 66

892

Battery Testing -Automatic. .................................................................. 66

892

General Options.  3. ............................................................................. 66

892

Keyswitch Zones Latching. .................................................................. 66

892

Pulse Count Handover. ........................................................................ 66

892

Siren Output To Operate As An Auxiliary ............................................ 66

893

General Options.  4. ............................................................................. 67

897

Fire alarms will activate the Siren. ...................................................... 67

897

Siren.  Emergency Alarms to activate Siren. ...................................... 67

897

Siren.  System Inputs to activate Siren. .............................................. 67

897

System Input Programming - Basic .................................................... 20

897

System Input Siren Enable .................................................................. 67

897 to 898

System Inputs ....................................................................................... 79

897 to 898

System Inputs Overview ...................................................................... 67

898

System Input Dialer Enable ................................................................. 68

899

Duress alarms will activate the Dialer. ................................................ 68

899

Duress Codes operation Enabled. ...................................................... 68

899

Emergency Alarm Programming - Basic ............................................ 20

899

Emergency Options ............................................................................. 68

899

Fire alarms will activate the Dialer. ..................................................... 68

899

Medical alarms will activate the Dialer. ............................................... 68

899

Medical alarms will activate the Siren. ................................................ 68

899

Panic alarms will activate the Dialer. .................................................. 68

899

Panic alarms will activate the Siren. ................................................... 69

Содержание CONCEPT IQ. PLUS

Страница 1: ...Ver 3 003 p1 CONCEPT IQ PLUS Programmer s Manual Programmer s Manual 2003 Inner Range Pty Ltd Part Number 630047plus PLUS...

Страница 2: ...er User Operations 15 6 2 User Programming 16 7 Basic Programming Guide 18 8 Programming of Advanced Features Contents and Overview 34 Access Control Options 35 Auto Arm Auto Disarm 36 Auxiliary to Fo...

Страница 3: ...s See the Tables section for a full description of each System Default option 4 Address Location Numerical Order Use Section 9 Programming Reference to program the system in numerical Address order 40...

Страница 4: ...d System Alarms such as Power Problems Cabinet Siren Tampers Communication Problems LAN Battery Fuses Zone Self test Status and Keypad Emergency Alarms Panic Fire Medical Duress System Inputs are also...

Страница 5: ...larm is activated if the line is tampered or the maximum attempts is reached Daily Weekly or Monthly Test reports can also be sent at a specified time of day or triggered manually by a Master User The...

Страница 6: ...Test Battery and Door Bell Enable Disable The Master User can also perform all User operations This includes Arming Dis arming the system Isolating Zones and View history The Master User automatically...

Страница 7: ...ep in response to Exit delay Entry delay or Auto arm warnings Multi Area systems Only Terminals associated with a particular Area will beep in response to that Area s warning functions IMPORTANT NOTE...

Страница 8: ...A reader need not be fitted if PIN only access is required The door will open for lock open time following a valid PIN OFF key For higher security applications both PIN and card can be required to op...

Страница 9: ...Module Select the Import Data Mode Enter PIN then then the Mode number The Lamp on the Programming Key will flash slowly to indicate data is being copied The Terminal beeper will sound 3 short beeps...

Страница 10: ...er entering the data will save the data and automatically take you to the Previous Address 4 PROGRAMMING TECHNIQUES TO EDIT THE DATA The Data Value at the Address selected will then be displayed via t...

Страница 11: ...digit Value data will display sequentially A chirp sounds as each digit is displayed 3 beeps indicate the end of the data sequence then the 1 lamp will flash to prompt for the 1st digit of the new dat...

Страница 12: ...phone Number Any existing data will now be displayed as described above 3 Enter the new Data string then 4 Select the next Address to program or Exit Programming Mode 4 7 OPTION DATA Option data is us...

Страница 13: ...e 1 Entry Exit Delayed Zone 2 is Type 2 Handover Zones 3 to 8 are Type 0 Instant Zones Zones 1 to 8 are set for siren lockout Zones 1 to 8 are in Area 1 Time Zone 1 is 0900 to 1700 Monday to Friday Ti...

Страница 14: ...splay Firmware Version The 4 digits of the current Controller Firmware Version will be displayed in sequence e g Sequence 3 0 0 0 V3 000 5 2 USER OPERATIONS REQUIRING PIN CODE ACCESS Installer Master...

Страница 15: ...tion or the nominated Domestic Dialer Telephone NEXT 26 Activates the Battery Test Switches the Battery Charger Off for 5 seconds to test Battery voltage 3 Beeps at end of Test Battery OK One long ton...

Страница 16: ...code is to be entered If the Zone Lamp flashes Slowly it indicates that a PIN Code is already programmed for this User If you enter a new PIN number it will replace the existing PIN number As each di...

Страница 17: ...one Lamps To confirm the selection Press 3 beeps will sound to confirm the new User Type has been programmed and the system will automatically advance to the next User number 8 Add Change another User...

Страница 18: ...n In many cases other options are available Simply ignore any options not listed These are not relevant to basic programming and are explained in the appropriate applications in Section 8 Programming...

Страница 19: ...Master Code Where n is the Default option 1 2 or 3 Completely resets the database to one of the Installer Presets including the Installer Code and Master Code See page 12 Defaulting the system and the...

Страница 20: ...vated when an alarm is triggered on this Zone NOTE Silent over rides Siren Lockout 2 Siren Lockout Zone will only trigger the Siren for the number of times specified in the Siren Swinger Shutdown Coun...

Страница 21: ...utomatically isolate when the Area is Armed at the end of the Exit Delay 2 Quick Arming No If selected no PIN Code required for arming Areas 3 Force Arm Areas No If selected Area will Arm regardless o...

Страница 22: ...following order hh mm 1st Field DD MM YY 2nd Field day 3rd Field i e Hour Hour Minute Minute Day Day Month Month Year Year Day Of Week Sunday 1 Monday 2 Tues 3 Wed 4 Thurs 5 Fri 6 Saturday 7 Key in th...

Страница 23: ...ssigned 4 Area 4 assigned Is the system a Multi Area system Single Area System NO YES Multi Area System Go to Step 14a Option Default Description 1 Multi Area system No 4 All Areas Siren Off control N...

Страница 24: ...DELAYS AS REQUIRED DEFAULT 60 Seconds Area 1 NEXT 541 Area 2 NEXT 542 Area 3 NEXT 543 Area 4 NEXT 544 Program a value from 0 to 255 Seconds Single Area System 16 PROGRAM THE TERMINAL ASSOCIATED AREA...

Страница 25: ...wed See Step 18 on page 25 for programming information Is the system required to Report to a Central Monitoring Station or a Telephone No Reporting NO YES Reporting is required Go to Step 30 Move on t...

Страница 26: ...ntered by pressing the OFF key e g To program a Press OFF 1 1 19 SELECT THE REPORTING FORMAT NEXT 505 Note If Option 8 is required select FIRST Refer to the Reference section page 41 42 for details of...

Страница 27: ...only if Dialer Option 5 General Open Close Reporting selected above DEFAULT Area 1 Assign the required Area s to the General Open Close Area List NOTE Area 1 must be included in the list 1 Include Ar...

Страница 28: ...ogram the Minute value from 0 to 59 25 PROGRAM THE DIALER LOCKOUT OPTION FOR ZONE INPUTS IF REQUIRED NEXT 651 to 666 23 PROGRAM THE MAXIMUM DIAL ATTEMPTS NEXT 508 DEFAULT 8 Attempts Program the Maximu...

Страница 29: ...efault Description 6 Delay Siren until Comms complete No Siren operation will not be initiated until a report has been sucessfully sent or a Comms Fail alarm generated 8 Dialer enabled in Home Mode No...

Страница 30: ...RF Module Enrol the User Wireless Remote Key by pressing a button on the Remote Key within 30 seconds of selecting the User number Three short beeps will sound to confirm that the Remote Key has been...

Страница 31: ...selected then press 5 Select the new User Type number then press See table below Delete a User 1 Key in your PIN then Select the User Number Press 2 Press then 0 Arm Only 1 Patrol Arm Disarm only aft...

Страница 32: ...e or Master User Code must be used to program this option 1 Key in your PIN then Press then to enable to disable default is disabled This option enables the OFF key on the Terminal to act as a REX but...

Страница 33: ...mming each individual feature Refer to the table of contents on the following page for a list of the features available 34 CHANGE THE INSTALLER PIN CODE NEXT 401 This should be done before the system...

Страница 34: ...A printer can be directly connected to the Controller via the on board Serial Port 39 Day Alarm A Zone Input can operate an Auxiliary output for activating Door Bells lights etc when disarmed 39 Defe...

Страница 35: ...wed Default setting is disabled requiring the Upload Download software addon to view the Access Review Door Forced to trigger Siren The Door Forced system input can be set to enable the Siren output w...

Страница 36: ...Holidays NEXT 570 571 Hol 1 to 588 589 Hol 10 Auto Arming Options Away Mode Choose the Area s to be controlled and select one TimeZone that will control the Area NEXT 551 Area 1 552 Area 2 0 No TimeZ...

Страница 37: ...Z2 764 TZ3 769 TZ4 Program any Holidays required to Qualify the TimeZone Any Days when Auxiliary Control is not to occur when the TimeZone would normally be Valid must be programmed as Holidays Progra...

Страница 38: ...l Beeper for Day Alarms in General Options 2 NEXT 891 3 Assign Event Type 16 Day Alarm to the selected Auxiliary to control NEXT 801 Aux 1 to 810 Aux 10 4 Program an Auxiliary Timer value for the sele...

Страница 39: ...x 10 101 Pre Warn Area 1 102 Pre Warn Area 2 103 Pre Warn Area 3 104 Pre Warn Area 4 b Check that the Auxiliary Action for the selected Auxiliary is set to Type 0 Follow Event Status NEXT 861 Aux 1 to...

Страница 40: ...en SPK Output Auxiliary 0 is required to operate as a normal Open Collector Auxiliary Output Enable Option 6 Siren Output operates as Auxiliary in General Options 3 NEXT 892 NOTE IF ENABLED A SIREN SP...

Страница 41: ...Aux 10 2 One shot timed in Seconds 3 One shot timed in Minutes Types 4 to 13 may also be suitable See Section 10 Tables page 71 for details of all Auxiliary Actions 4 Program one or more User PIN Cod...

Страница 42: ...he Auxiliary to control and select Event Type 17 RF Auxiliary NEXT 801 Aux 1 to 810 Aux 10 b Program an Auxiliary Timer value for the selected Auxiliary NEXT 831 Aux 1 to 840 Aux 10 c Assign the requi...

Страница 43: ...t setting is 4 Digits User Programming Each User programmed into the system is assigned a PIN Code the Areas that they are allowed to control and a User Type If the system has one or more Wireless Rem...

Страница 44: ...ber If this fails the dialer will alternate between the two numbers until the Maximum Attempts Address 508 are reached CALL DIVERT CALL FORWARDING TELEPHONE NUMBER UP TO 16 DIGITS Call Divert will onl...

Страница 45: ...s heard the User can simply hang up the telephone IMPORTANT NOTES Once the receiving telephone has answered the call the alarm message is regarded as being acknowledged and will not be sent again rega...

Страница 46: ...e Dual reporting you must always select the Dual Reporting option Option 8 first SAME FORMAT For Dual reporting of the same format simply select the format that you wish to report in Option 1 or 2 DIF...

Страница 47: ...must be included in the list When reporting in Contact ID format General Open Close reporting only uses the Area 1 Client Code programmed at Address 521 1 Include Area 1 in the General Open Close Are...

Страница 48: ...EST REPORT HOUR 0 23 HOUR This Address sets the hour that the test report will be sent TEST REPORT MINUTE 0 59 This Address sets the minute the test report will be sent REMOTE CONNECT OPTIONS These op...

Страница 49: ...is trying to remotely connect to the system and an Answering Machine is connected to the same Telephone line If this feature is enabled the remote device must call the system then hang up within thre...

Страница 50: ...This is the 4 digit Client Code that will be used for Single Area systems Area 1 or General Open Close reporting in Multi Area systems AREA 2 CLIENT CODE This is the 4 digit Client Code used for Area...

Страница 51: ...ERAL AREA AREA 1 EXIT DELAY TIME AREA 2 EXIT DELAY TIME AREA 3 EXIT DELAY TIME AREA 4 EXIT DELAY TIME Note Area 4 Exit Delay is not used when Armed as a Sub Area The controlling Area Exit Delay is use...

Страница 52: ...Exit Delay applies to the Area the Exit Delay will start at the end of the Auto Arm Pre Warn Time 5 If Area Auto Disarm function is required program the Area Auto Disarm Options in Address 559 AREA 1...

Страница 53: ...ed Area if the User has permission See User manual for details Multi Area Mode PIN Code ON OFF Arms Disarms all Areas PIN Code Area Number ON OFF Arms Disarms the specified Area if the User has permis...

Страница 54: ...dress locations for defining the Holiday Month and the Day of the month Any TimeZone that is not set to be Valid on Holidays will be Invalid on any date defined as a Holiday HOLIDAY MONTH 0 12 This Ad...

Страница 55: ...DAYLIGHT SAVING DAY OF WEEK IN START WEEK 1 7 This Address sets the Day Of Week component of the Date for the Start of Daylight Saving 1 Sunday 4 Wednesday 6 Friday 2 Monday 5 Thursday 7 Saturday 3 T...

Страница 56: ...esting are programmed as global Zone Options END OF LINE RESISTOR TYPE This data sets the value s of the End Of Line Terminating resistor s used for the Zone inputs This is a global setting for all Zo...

Страница 57: ...the same whether Armed in Normal Mode or Home Mode 2 Hand over When a Handover Zone goes into alarm the alarm will be processed under these two conditions If a Delayed Zone has already been triggered...

Страница 58: ...n is triggered a Panic siren tone will sound If the dialer is enabled a Panic report is sent to the Central Station 13 24 Hour Duress A 24 Hour Duress Zone is permanently armed Duress alarm processing...

Страница 59: ...iren Lockout This option allows the Zone to trigger the Siren only for the number of times specified in Swinger Shutdown Siren Count Address 913 during one arming cycle If Silent and Siren Lockout opt...

Страница 60: ...efined as a Day Alarm then when the Area that the Zone is assigned to is Dis armed the Zone can trigger an Auxiliary that has the Day Alarm Event Type assigned Address 800 to 810 Event Type 16 When th...

Страница 61: ...TIMEZONE 2 PROGRAMMING TIMEZONE 3 PROGRAMMING TIMEZONE 4 PROGRAMMING Each TimeZone has 5 Address locations for defining Start Hr Start Min End HrEnd Min Valid Days of the Week START AND END TIMES The...

Страница 62: ...es the period of time the Auxiliary will be activated if a Timed Auxiliary Action is selected The Auxiliary Action must be programmed to define the way in which the Auxiliary is controlled AUXILIARY E...

Страница 63: ...on Door One 141 DOTL Alarm on Door One AUXILIARY TIMER VALUE These Addresses allow a Timer Value to be programmed for any Auxiliary Actions that incorporate a Timer Auxiliary Actions 2 to 13 The Timer...

Страница 64: ...nly the associated Area can be Armed Force Arm Areas When enabled Users can arm Areas in Away mode or Home mode regardless of any un sealed Zones Un sealed Zones in the Area will be Isolated if the Au...

Страница 65: ...s recommended Bell Squawk on Siren for Wireless operations Squawk is 200mS Tone burst in a 1 second period Arm Button 1 1 Squawk Disarm Button 2 2 Squawks Error Already Armed 5 Squawks DTMF Control IM...

Страница 66: ...ighly recommended as a Low Battery Alarm can only be generated if the battery falls below 10 5V during a Battery Test or when the AC input is not present When this function is enabled the system will...

Страница 67: ...Fault History function NEXT 13 This function uses the Zone Lamps to display any System Inputs that have had an alarm in the last 5 Arming periods Flashing Currently in alarm ON Historical alarm To ena...

Страница 68: ...erated by Keypad Fire Siren Dialer options for 24Hr Fire Zones are determined by Zone Options Medical alarms generated by Keypad Medical Duress alarms generated by Keypad Duress AND Zone Inputs progra...

Страница 69: ...ata sets the number of arming periods to be included in the Zone Self Test processing Any Zone defined as a Self Test Zone must go un sealed at least once during this Self Test period or a Self Test s...

Страница 70: ...is required ensure that Automatic Battery testing is enabled Address 892 Option 2 keep the delay period as short as possible and advise the system Owner User of the implications of the function AUTO A...

Страница 71: ...y being detected the Area will automatically arm 3 It is recommended that the Auto Arm Pre Warn Time Address 907 and or Area Exit Delay Time Address 541 to 544 is programmed for the Area s to provide...

Страница 72: ...an trigger the Dialer before Dialer Lockout Only alarms on Zones with Dialer Lockout Address 651 666 Option 3 enabled will increment the counter When the count is met any further activation of the Dia...

Страница 73: ...normal operation is card or PIN Terminal One Door One only accepts CARD PIN Data Factory Default not Enabled Terminal Two Door Two only accepts CARD PIN Data Factory Default not Enabled Terminal Thre...

Страница 74: ...CEPT IQ PLUS Programmer s Manual 10 TABLES Auxiliary Event Types 75 77 Auxiliary Actions 78 System Inputs 79 Contact ID Event Codes 80 Factory Default and Installer Preset configurations 81 84 Printer...

Страница 75: ...en Close Area List Disarmed Address 607 Single Area system Area 1 Disarmed Multi Area system Any Area in the General Open Close Area List Armed 7 Smoke Detector Reset PIN code OFF is entered at a Term...

Страница 76: ...In Home Mode Area Armed in Home mode Area Dis armed 92 Area 2 Armed In Home Mode 93 Area 3 Armed In Home Mode 94 Area 4 Armed In Home Mode 101 Area 1 Auto Arm Prewarn Auto Arm Pre warn started in the...

Страница 77: ...pe is used to fire DC buzzers placed in close proximity to access doors 132 Door Forced or DOTL Alarm on Door 2 133 Door Forced or DOTL Alarm on Door 3 134 Door Forced or DOTL Alarm on Door 4 135 n a...

Страница 78: ...when Event goes Invalid 7 One Shot with Reset timed in Minutes On when Event goes Valid for a time period specified in Minutes Off when timer expires or when Event goes Invalid 8 One Shot on Invalid w...

Страница 79: ...uit or over current condition The fuse has been replaced Battery Fuse fail 106 6 Battery fuse has blown Due to Short circuit or over current condition The fuse has been replaced Comms Fail 107 7 Syste...

Страница 80: ...o 04 001 to 016 2 Handover 130 01 to 04 001 to 016 3 24hr Burglary 130 01 to 04 001 to 016 4 24hr Fire 110 01 to 04 001 to 016 5 24hr Panic 120 01 to 04 001 to 016 6 24hr Duress 121 01 to 04 001 to 01...

Страница 81: ...0 532 Area 2 Entry Delay Time 30 30 30 30 533 Area 3 Entry Delay Time 30 30 30 30 534 Area 4 Entry Delay Time 30 30 30 30 541 General Area Area 1 Exit Delay Time 60 60 60 60 542 Area 2 Exit Delay Time...

Страница 82: ...Light Savings Start Week 5 5 5 5 592 Day Light Savings Day of Week Start 1 1 1 1 593 Day Light Savings End Month 0 0 0 0 594 Day Light Savings End Week 5 5 5 5 595 Day Light Savings Day of Week End 1...

Страница 83: ...me Zone 2 Start hour 9 9 9 9 756 Time Zone 2 Start Minute 0 0 0 0 757 Time Zone 2 End Hour 13 13 13 13 758 Time Zone 2 End Minute 0 0 0 0 759 Time Zone 2 Valid days of the week 1 7 1 7 1 7 1 7 760 Tim...

Страница 84: ...0 0 0 0 897 System Input Siren Enable 3 3 3 3 898 System Input Dialer Enable 1 2 3 5 6 7 0 1 2 3 5 6 7 1 2 3 5 6 7 899 Emergency Options 1 2 3 5 6 1 3 5 1 2 3 5 6 7 1 2 3 5 6 7 900 Home Zone Entry De...

Страница 85: ...Task Address 515 or 517 option 2 the Review history is sent to that serial port A SERIAL printer is required using the baud rate set for the serial port Address 516 or 518 option 3 default is 9600 8...

Страница 86: ...g Overview 800 to 870 62 Auxiliary Timer Value 830 to 840 63 Auxiliary To Follow A Timezone 37 Basic Programming Guide 1 16 Zone Alarm System 18 Battery Test Manual 26 15 Battery Test on Arming 892 66...

Страница 87: ...neral User Operations 11 to 15 14 Handover Force Arm Zone Type 601 to 616 58 Handover Zone Type 601 to 616 57 Holiday Day 570 54 Holiday Month 571 54 Holidays 570 to 589 54 Home Zone Types 601 to 616...

Страница 88: ...e Siren 897 67 Siren System Inputs to activate Siren 897 67 Six Digit Pin Codes 40 Smoke Detector Reset 41 Special Siren Tone for System Alarms 890 64 Strobe Programming Basic 801 22 Sub Area Operatio...

Страница 89: ...on after Disarm 890 64 Zone Areas 701 to 716 60 Zone Input Programming Basic 600 to 666 19 20 Zone Input Programming Overview 601 to 716 56 Zone Options 651 to 666 59 Zone Self Test History 14 14 Zone...

Страница 90: ...divert Cancel Call Forwarding Telephone No 44 504 Call back Telephone Number 45 505 Contact ID Event Codes 80 505 Contact ID Reporting Format 45 505 Domestic Dialer Reporting Format 45 505 Dual Repor...

Страница 91: ...64 890 Force Arm Areas 64 890 General Option Programming Basic 21 890 General Options 1 64 890 Quick Arming 64 890 Single Exit Beep in Home Mode 64 890 Special Siren Tone for System Alarms 64 890 Zon...

Страница 92: ...Lockout Time 70 906 AC Report Delay 70 907 Auto arm Pre warn Time 70 908 Re auto arm Time 70 909 RF Terminal Auxiliary Time 71 910 Siren Hold off Time 71 911 24 Hr Fire Zone Smoke Detector Ignore Tim...

Страница 93: ...Ver 3 003 p93 CONCEPT IQ PLUS Programmer s Manual...

Страница 94: ...it should be returned to the distributor and the fault or symptom detailed Inner Range will at its own discretion repair or replace the product as soon as possible This Warranty does not cover produc...

Отзывы: