p76
Ver. 3.003 (24/4/03)
CONCEPT IQ. PLUS Programmer’s Manual.
No. Auxiliary Event Type:
Event On (Valid) when:
Event Off (Invalid) when:
28
Zone 8 in Alarm
Zone in Alarm.
(When Area is Armed)
Must be programmed to turn Off by Auxiliary Timer.
29
Zone 9 in Alarm
30
Zone 10 in Alarm
31
Zone 11 in Alarm
32
Zone 12 in Alarm
33
Zone 13 in Alarm
34
Zone 14 in Alarm
35
Zone 15 in Alarm
36
Zone 16 in Alarm
71
Timezone 1
TimeZone Valid.
TimeZone Invalid or Off by Auxiliary Timer
72
Timezone 2
73
Timezone 3
74
Timezone 4
81
Area 1 Armed
Area Armed in Away (Normal) mode or Home mode.
If an Exit Delay is programmed for the Area, the Event is turned On at the start of the
Exit Delay.
Area Dis-armed .
82
Area 2 Armed
83
Area 3 Armed
84
Area 4 Armed
91
Area 1 Armed In Home Mode
Area Armed in Home mode.
Area Dis-armed.
92
Area 2 Armed In Home Mode
93
Area 3 Armed In Home Mode
94
Area 4 Armed In Home Mode
101
Area 1 Auto Arm Prewarn
Auto-Arm Pre-warn started in the specified Area.
The Pre-warn timer is programmed in Address 007.
Auto-Arm Pre-warning expired. (Area on)
102
Area 2 Auto Arm Prewarn
103
Area 3 Auto Arm Prewarn
104
Area 4 Auto Arm Prewarn
111
Alarm. General Area / Area1
Any Alarm in the specified Area.
Operates in either Away (Normal) mode or Home mode.
Area Disarmed.
112
Alarm. Area 2
113
Alarm. Area 3
114
Alarm. Area 4
121
Entry / Exit. General Area / Area 1
Entry or Exit timer running in the specified Area.
Entry or Exit timer cancelled or expired in Area.
122
Entry / Exit. Area 2
123
Entry / Exit. Area 3
124
Entry / Exit. Area 4
NOTE:
Auxiliary Event Type numbers have been structured in a logical manner to cater for expansion while providing a common Event numbering system across all
Concept IQ Versions.