9.
ENABLE/DISABLE ANY BASIC GENERAL SYSTEM OPTIONS THAT ARE REQUIRED FROM “GENERAL OPTIONS 1”.
NEXT 890
8.
PROGRAM THE BASIC SYSTEM TIMERS.
HomeGuard Time.
DEFAULT: 90 Seconds.
NEXT 900
Program a value from 0 to 255 Seconds. Sets the Home Zone Entry Delay time for the “Home Delayed” function in Zone Types 4, 6 & 8.
Siren Time.
DEFAULT: 5 Minutes.
NEXT 904
Program a value from 0 to 255 Minutes.
Keypad Lockout Time.
DEFAULT: 5 Minutes.
NEXT 905
Program a value from 0 to 255 Seconds. Sets the time that keypad operation will be disabled after 5 incorrect login (PIN Code) attempts.
AC Report Delay Time.
DEFAULT: 0 Minutes.
NEXT 906
Program a value from 0 to 255 Minutes. Sets the time that the AC must be continuously disconnected before an AC Fail alarm is generated.
Siren Holdoff Time.
DEFAULT: 0 Seconds.
NEXT 910
Program a value from 0 to 255 Seconds. Sets the time that the activation of the External Siren will be delayed after an alarm occurs.
Fire Zone (Smoke Detector) Ignore Time.
DEFAULT: 60 Seconds.
NEXT 911
Program a value from 0 to 255 Seconds. Sets the time that activity on “24 Hour Fire” Zone Types will be ignored after a Smoke Detector Reset occurs.
t
Option
Default
Description
1
Auto-Isolate on Arming.
No
If selected, unsealed Zones will automatically isolate when the Area is Armed at the end of the Exit Delay.
2
Quick Arming.
No
If selected, no PIN Code required for arming Areas.
3
Force Arm Areas.
No
If selected, Area will Arm regardless of any unsealed Zones.
If “Auto-Isolate on Arming” is selected, any unsealed Zones will be Isolated. If not, unsealed Zones will go into alarm.
4
Clock Synchronized to 50Hz AC Mains.
Yes
Only Disable if Mains supply frequency is not stable, or if Controller is only powered by a DC supply.
5
Zone Alarm indication after Disarm.
Yes
Terminal automatically goes to Alarm History Display when Disarmed if an Alarm has occurred in that Area.
6
Display Zone activity when Disarmed.
Yes
Enables display of Zone activity via the Terminal Zone LED’s when Area/System is Disarmed.
7
Special Siren Tone for System Inputs
Yes
Special Siren Tone used for System Inputs that are programmed to activate the Siren.
No = Normal Burglary Siren Tone. (Default setting)
Yes = 1 Sec bursts for 4.25 minutes unless cancelled by PIN Code.
8
Single Exit Beep in Home Mode.
Yes
If selected, Exit beeps are replaced with a single beep at start of Exit Delay when Armed in Home Mode.
How to Enter Data.
Select Address: Key in the Installer PIN Code; Press
then enter the 3 digit Address
(A1 to A3 Lamps will flash to prompt for each digit). The current Data will be displayed.
Enter Data:
Enter the new Data
.. (1-16 digits) OR Option/s to Select/De-select
, then
. NOTE:
clears the current field of all data or settings ready for new data.