AUTO-ARM AND AUTO-DISARM
Program a TimeZone.
1) Choose a TimeZone to Program.
2) Program a “Start Time”. This is the time that the Area will automatically Arm.
Program the Start Hour.
NEXT 750 (TZ1), 755 (TZ2), 760 (TZ3), 765 (TZ4)
Program the Start Minute.
NEXT 751 (TZ1), 756 (TZ2), 761 (TZ3), 766 (TZ4)
3) Program an “End Time”. This is the time that the Area will automatically Disarm (If Auto-Disarm enabled)
Program the End Hour.
NEXT 752 (TZ1), 757 (TZ2), 762 (TZ3), 767 (TZ4)
Program the End Minute.
NEXT 753 (TZ1), 758 (TZ2), 763 (TZ3), 768 (TZ4)
4) Assign the Days-of-the-Week when the TimeZone will operate.
1 - Sun.
2 - Mon.
3 - Tues.
4 - Wed
5 - Thurs
6 - Fri.
7 - Sat.
8 - Hol.
NEXT 754 (TZ1), 759 (TZ2), 764 (TZ3), 769 (TZ4)
Program any Holidays required to Qualify the TimeZone
Any Days when Auto-Arming/Disarming is not to occur, when the TimeZone would normally be Valid, must be programmed as Holidays.
Program the Holiday Month (0 - 12) and the Holiday Date (0 - 31) for up to 10 Holidays.
NEXT 570 & 571 (Hol 1) to 588 & 589 (Hol 10)
Auto-Arming Options. Away Mode.
Choose the Area/s to be controlled and select one TimeZone that will control the Area.
NEXT 551 (Area 1), 552 (Area 2),
0 - No TimeZone Control. 1 - TZ1.
2 - TZ2.
3 - TZ3.
4 - TZ4.
NEXT 553 (Area 3), 554 (Area 4)
If any Areas are to Auto-Arm in Home Mode, program the “Auto-Arm in Home Mode” Options.
Select the Area or Areas for Auto-Arming in Home Mode.
NEXT 560
1 - Area 1.
2 - Area 2.
3 - Area 3.
4 - Area 4.
If Auto-Disarming is also required, program the Area Auto-Disarm Options.
Select the Area or Areas for Auto-Disarming.
NEXT 559
1 - Area 1.
2 - Area 2.
3 - Area 3.
4 - Area 4.
Program the Auto-Arm Pre-Warn Time. (Factory Default = 255 seconds)
Program the warning time required before Auto-Arm occurs. (Via the Terminal Beeper)
NEXT 907
Program an Auxiliary Output if required to activate an additional Warning sounder.
1) Choose the Auxiliary to control and select the “Auxiliary Event Type”.
NEXT 801 (Aux 1), to 810 (Aux 10)
101 - Pre-Warn Area 1.
102 - Pre-Warn Area 2.
103 - Pre-Warn Area 3.
104 - Pre-Warn Area 4.
2) Check that the “Auxiliary Action” for the selected Auxiliary is set to Type 0 - “Follow Event Status”.
NEXT 861 (Aux 1), to 870 (Aux 10)