Ver. 3.003
p61
CONCEPT IQ. PLUS Programmer’s Manual.
Any Zone not assigned to any Area is considered as an unused Zone.
Programming Addresses for Zone Area programming:
This data sets the Area/s that the Zone will be assigned to.
Zones are normally only assigned to one Area.
A separate Address is used for each Zone Input as per the table above.
TIMEZONES
TimeZones can be programmed to define a Start time and End time, and the Days of the Week on which the TimeZone will be valid.
TimeZone programming also provides a “Holiday” option to be enabled when assigning the Days, to allow the TimeZone to still be valid on
any dates defined as Holidays.
Once programmed, TimeZones can be used to arm & disarm Areas &/or control Auxiliary outputs automatically.
TIMEZONE 1 PROGRAMMING.
TIMEZONE 2 PROGRAMMING.
TIMEZONE 3 PROGRAMMING.
TIMEZONE 4 PROGRAMMING.
Each TimeZone has 5 Address locations for defining:
Start Hr
Start Min
End HrEnd Min
Valid Days of the Week
START AND END TIMES
The Start and End Times are defined in 4 separate Addresses for each TimeZone.
TIMEZONE START HOUR
(0 - 23 Hour)
This Address defines the Hour component of the Start Time.
TIMEZONE START MINUTE
(0 - 59 Minute)
This Address defines the Minute component of the Start Time.
TIMEZONE END HOUR
(0 - 23 Hour)
This Address defines the Hour component of the EndTime.
TIMEZONE END MINUTE
(0 - 59 Minute)
This Address defines the Minute component of the End Time.
717-749
750-754
755-759
760-764
765-769
Zones 1 to 8
1 - Area 1
Zones 9 to 16
No Areas assigned.
Spare
9am-5pm Mon to Fri
9am-1pm Sat & Sun
7am-8pm All days
8pm-7am All days
(Value Data)
ADDRESS
DEFAULT
FUNCTION
(Data Type)
Zone
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Address
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716