p72
Ver. 3.003 (24/4/03)
CONCEPT IQ. PLUS Programmer’s Manual.
ADDRESS
DEFAULT
FUNCTION
(Data Type)
exiting. The timer will be cancelled if the Walk Test is exited by pressing the <CLR> key on the Terminal.
SIREN SWINGER SHUTDOWN COUNT (0 - 255)
Number of times Zone Input alarms can trigger the Siren before Siren Lockout. Only alarms on Zones with “Siren Lockout” (Address 651 -
666, Option 2) enabled will increment the counter. When the count is met any further activation of the Siren by these Zones will be locked
out.
(i.e. Zones without the “Siren Lockout” option enabled, and system alarms such as Panic, Max PIN attempts, etc. cannot increment the
counter and Siren operation will not be locked out for these alarms)
The Counter is reset when the Area is turned Off by any method.
Note that a Siren Swinger Shutdown value of 0 will disable Siren operation for alarms on all Zones with “Siren Lockout” enabled.
DIALER SWINGER SHUTDOWN COUNT (0 - 255)
Number of times Zone Input alarms can trigger the Dialer before Dialer Lockout. Only alarms on Zones with “Dialer Lockout” (Address 651
- 666, Option 3) enabled will increment the counter. When the count is met any further activation of the Dialer by these Zones will be
locked out.
(i.e. Zones without the “Dialer Lockout” option enabled, and system alarms such as Panic, Max PIN attempts, etc. cannot increment the
counter and Siren operation will not be locked out for these alarms)
The Counter is reset when the Area is turned Off by any method.
Note that a Dialer Swinger Shutdown value of 0 will disable Dialer operation for alarms on all Zones with “Dialer Lockout” enabled.
ACCESS OPTIONS
REX
when enabled the OFF key, on the Terminal, will operate the lock auxiliary for the lock open time.
Terminal One OFF / # key is recognised as a valid REX. (Factory Default not Enabled)
Terminal Two OFF / # key is recognised as a valid REX. (Factory Default not Enabled)
Terminal Three OFF / # key is recognised as a valid REX. (Factory Default not Enabled)
Terminal Four OFF / # key is recognised as a valid REX. (Factory Default not Enabled)
n/a
n/a
n/a
n/a
913
914
915-917
918
16
16
SPARE
(Option Data)
1 - No
2 - No
3 - No
4 - No
5 - No
6 - No
7 - No
8 - No