Ver. 3.003
p53
CONCEPT IQ. PLUS Programmer’s Manual.
AUTO-ARM IN HOME MODE
If an option is selected, the Area will Auto-arm in Home mode when the TimeZone (If assigned in the Area Auto-Arming Options) becomes
Valid. Area Auto-Arming Options are programmed in Addresses 551 (Area 1) to 554 (Area 4).
See additional notes under Area Arming Options, Address 551 to 554.
1 - Auto-Arm Area 1 in Home Mode.
2 - Auto-Arm Area 2 in Home Mode.
3 - Auto-Arm Area 3 in Home Mode.
4 - Auto-Arm Area 4 in Home Mode.
TERMINAL ASSOCIATED AREA
(0 - 4)
Associating the Areas for each Terminal has three functions:
1. Defines how Arming & Disarming operations from the Terminal are performed.
•
Single Area Mode: PIN Code, <ON>/<OFF>; Arms/Disarms only the Area associated with the Terminal.
PIN Code, <Area Number>, <ON>/<OFF>; Arms/Disarms the specified Area if the User has permission.
See User manual for details.
•
Multi-Area Mode: PIN Code, <ON>/<OFF>; Arms/Disarms all Areas.
PIN Code, <Area Number>, <ON>/<OFF>; Arms/Disarms the specified Area if the User has permission.
See User manual for details.
2. Defines what Zone information will be displayed on the Terminal.
•
Single Area mode: Only Zones in the associated Area will be displayed on the Terminal Zone Lamps.
•
Multi-Area mode: Zones in all Areas will be displayed on the Terminal Zone Lamps.
NOTE: If Zone activity is required to be displayed on Terminals when the System / Associated Area is Disarmed, Address 890 (General
Options 1), Option 6 must be selected.
3. Selects which Area the Terminal will sound Entry/Exit warnings for.
0 - Multi-Area
1 - Area 1
3 - Area 3
2 - Area 2
4 - Area 4
TERMINAL 1 ASSOCIATED AREA (0 - 4)
TERMINAL 2 ASSOCIATED AREA (0 - 4)
TERMINAL 3 ASSOCIATED AREA(0 - 4)
560
561
562
563
(Option Data)
1 - No
2 - No
3 - No
4 - No
(Value Data)
0 - Multi-Area
0 - Multi-Area
0 - Multi-Area
ADDRESS
DEFAULT
FUNCTION
(Data Type)