CONCEPT IQ. PLUS Programmer’s Manual.
ADDRESS
DEFAULT
FUNCTION
(Data Type)
GENERAL OPTIONS. 4.
ACCESS OPTIONS
1 - Enable reporting of Door Forced event
2 - Enable reporting of Door Open Too Long event
3 - Enable Access review written into eeprom
SYSTEM INPUTS OVERVIEW
System Inputs are system events that can generate alarms.
System Inputs have three programmable options; Siren enable, Dialer enable and Siren tone. Siren enable and Dialer enable are
programmed individually for selected System Inputs, while the Siren tone setting applies to all System Inputs that can activate the Siren.
System Inputs are always enabled. When in alarm, System Inputs that represent Fault or Tamper conditions will be indicated by the “Fault”
Lamp on the LED Terminal.
Details of individual System Input alarms can be viewed via the “View Fault History” function, NEXT 13. This function uses the Zone Lamps
to display any System Inputs that have had an alarm in the last 5 Arming periods.
Flashing
= Currently in alarm.
ON
= Historical alarm.
To enable selected System Inputs to activate the Siren and/or Dialer, the “Siren Enable” and “Dialer Enable” options must be programmed.
See the Tables Section, page 75, at the rear of this manual for full details of System Input operation and mapping details.
SYSTEM INPUT SIREN ENABLE
Siren operation for various System Inputs can be enabled by selecting the required System Input siren enable options.
1 - AC fail
2 - Low battery
3 - Cabinet Tamper
4 - Keypad Lockout
5 - Comm Fail / System Reset / Real-Time-Clock Problem
6 - Siren Monitor
7 - PWR Fuse / Battery Fuse
8 -
Door Forced Alarm
Keypad Lockout. This function is normally enabled (via the defaults) with a “Keypad Lockout Time” of 60 seconds. To disable, set the
Lockout time to zero. (Address 905)
893
894-896
897
(Option Data)
1 - No
2 - No
3 - No
Spare.
(Option Data)
1 - No
2 - No
3 - Yes
4 - No
5 - No
6 - No
7 - No
8 - No