CONCEPT IQ. PLUS Programmer’s Manual.
AUXILIARY EVENT TYPES
This table is continued on the following page.
NOTE:
Auxiliary Event Type numbers have been structured in a logical manner to cater for expansion while providing a common Event numbering system across all
Concept IQ Versions.
No. Auxiliary Event Type:
Event On (Valid) when:
Event Off (Invalid) when:
0
User (Master) Control/Test only
Turned On via NEXT 24 "Auxiliary Control & Test" Mode.
Turned Off via NEXT 24 "Auxiliary Control & Test" Mode.
1
Burglary Alarm (Strobe)
Any Burglary alarm. (Alarm on Zone Types 0, 1, 2 or 3)
The Area that the Alarm occured in, is Disarmed (Turned Off).
2
Fire Alarm
Any Fire alarm . (Alarm on Zone Type 4)
System Dis-armed (Any Area is disarmed) or PIN <OFF> entered.
3
Zone Bypass on Arming
Any Zone Automatically or Manually Bypassed (Isolated) on arming an Area.
Any Area turned off or All Zones De-Isolated.
4
System Alarm
Any System Input in alarm.
No System Input remaining in alarm.
5
System Armed
System fully Armed. Single Area system -Area 1 Armed.
Multi Area system -All Areas in the General Open/Close Area List Armed. (Address
607)
Single Area system -Area 1 Armed.
Multi-Area system -Any Area in the General Open/Close Area List
Disarmed.
6
System Disarmed
System fully Disarmed. Single Area system -Area 1 Disarmed.
Multi Area system -All Areas in the General Open/Close Area List Disarmed. (Address
607)
Single Area system -Area 1 Disarmed.
Multi-Area system -Any Area in the General Open/Close Area List Armed.
7
Smoke Detector Reset
PIN code, <OFF> is entered at a Terminal after a Fire Zone has been activated.
Must be programmed to turn Off by an Auxiliary Timer.
8
Comms Fail
System failed to report. Follows Comms Fail System Input.
On the next successful dialer communication.
9
External Siren
External Siren (SPK Output) active.
Siren off.
10
Internal Siren
Siren Timer or Siren Hold-off Timer Started.
Siren off.
11
Entry Timer (Any Area)
Any Area Entry timer on.
Entry timer off.
12
Exit Timer (Any Area)
Any Area Exit timer on.
Exit timer off.
13
User Auxiliary A.
PIN Code entered by User Type 4.
Should be programmed to turn Off by Auxiliary Timer.
14
User Auxiliary B.
PIN Code entered by User Type 5.
Should be programmed to turn Off by Auxiliary Timer.
15
Day Alarm.
Any “Day alarm” Zone Type Unsealed when Area not Armed.
Must be programmed to turn Off by an Auxiliary Timer.
16
Bell Squawk
RF Wireless remote action activates Bell Squawk on Siren.
Arm (Button 1) - 1 Squawk.
Disarm (Button 2) - 2 Squawks.
Home Arm (Button 3) / Aux Control (Button 4) - NO Squawks.
Error (Area already Armed) - 5 Squawks.
Follows Event
17
RF Auxiliary
RF Wireless remote Button 4
Must be programmed to turn Off by Auxiliary Timer.
21
Zone 1 in Alarm
Zone in Alarm.
(When Area is Armed)
Must be programmed to turn Off by Auxiliary Timer.
22
Zone 2 in Alarm
23
Zone 3 in Alarm
24
Zone 4 in Alarm
25
Zone 5 in Alarm
26
Zone 6 in Alarm
27
Zone 7 in Alarm