p58
Ver. 3.003 (24/4/03)
CONCEPT IQ. PLUS Programmer’s Manual.
7
Away Delayed / Home Instant.
Same as Type 1 - “Delayed” when Armed in Away (Normal) Mode.
Instant Alarm when Armed in Home Mode.
8
Away Handover / Home Isolate.
Same as Type 2 - “Handover” when Armed in Away (Normal) Mode.
Isolated when Armed in Home Mode.
9
Away Handover / Home Delayed.
Same as Type 2 - “Handover” when Armed in Away (Normal) Mode.
Delayed by the “Homeguard Time” (Address 900) when Armed in Home Mode.
10
24 Hour Burglary
A “24 Hour Burglary” Zone is permanently armed. When the Zone goes into alarm it can trigger the sirens, strobe,
and other outputs and report the alarm according to how the processing options are programmed.
If the siren is triggered a Burglary siren tone will sound. Note: 24 Hr Zone Types must still be assigned to an Area.
11
24 Hour Fire A “24 Hour Fire” Zone is permanently armed. When the Zone goes into alarm it can trigger the sirens, strobe, and other
outputs and report the alarm according to how the processing options are programmed.
If the siren is triggered a Fire siren tone will sound. Note: 24 Hr Zone Types must still be assigned to an Area.
12
24 Hour Panic
A “24 Hour Panic Zone” is permanently armed. Panic alarm processing is determined by the “Emergency Options”.
(Address 899, Options 1 & 2). Note: 24 Hr Zone Types must still be assigned to an Area.
If the siren is triggered a Panic siren tone will sound. If the dialer is enabled a “Panic” report is sent to the Central Station.
13
24 Hour Duress
A “24 Hour Duress Zone” is permanently armed. Duress alarm processing is determined by the “Emergency
Options”. (Address 899, Option 7) Note: 24 Hr Zone Types must still be assigned to an Area. If the dialer is enabled a “Duress” report is
sent to the Central Station.
14
*Key Switch Arming A “Key Switch“ Zone will arm the Area it is assigned to when the Zone goes Un-sealed.
The Zone can be programmed for momentary or latching operation in “General Options 3”. (Address 892, Option 5. Default setting is
“Latching”)
15
*Key Switch HOME A “Key Switch HOME” Zone will Arm the Area it is assigned to in HOME mode when the Zone goes Un-sealed.
The Zone can be programmed for momentary or latching operation in “General Options 3”. (Address 892, Option 5. Default setting is
“Latching”)
* NOTE: “Key Switch” Zones can be used to Disarm Area 4 when enabled as a Sub-Area, but Area 4 will not Arm unless all the Areas in
the Sub-Area List are Armed.
16
Delayed Force Arm. Same operation as Type 1 - “Delayed” except that Users will always be allowed to arm an Area assigned to
this Zone type when the Zone is unsealed. i.e. The “Force Arming” function will always apply regardless of the setting in General
Options 1, Option 3 - Force Arming. (Address 890. Default is “Not Enabled”)
Allows for Delayed Zones that may need to be unsealed when arming. e.g. A PIR that detects movement near the Terminal, or a
Reed switch on a Security Shutter at the Entrance.