2. THE LED TERMINAL
PANIC.
Keys 1 & 3 pressed simultaneously.
FIRE.
Keys 4 & 6 pressed simultaneously.
MEDICAL. Keys 7 & 9 pressed simultaneously.
REX
(Request to Exit)
<OFF> key.
Enhanced Terminals only.
2.1 KEY FUNCTIONS.
NEXT
-Installer:
Select a Programming Address or Installer operation.
-Master User:
Select a Master User operation.
HOME
-In Single Area Mode:
Used to Arm the system in Home Mode.
-In Multi-Area Mode:
Used to Arm the specified Area in Home Mode.
-Master User:
Clear the data already entered if you make a mistake.
CLR
Logoff the Terminal.
Exit the current Mode of operation)
ENTER
Saves the data entered in a programming Address.
NOTE:
AUTO-LOGOFF: The Terminal will automatically logoff the operator if there is
no keypad activity detected for 30 seconds.
2.2 BEEPER INDICATIONS.
2 or 3 Short Beeps:
A User, Master or Installer function was successful.
1 Long Beep:
A User, Master or Installer function has been unsuccessful.
When an error is detected, the beeper tones will sound at a
lower pitch until a correct operation is successfully performed.
Continuous Short Beeps
*
:
Entry Delay Timer, Exit Delay Timer or Auto-arm Warning.
*
NOTE:
Single Area systems.
All Terminals will beep in response to Exit delay, Entry delay or
Auto-arm warnings.
Multi-Area systems.
Only Terminals associated with a particular Area will beep in
response to that Area’s warning functions.
IMPORTANT NOTE: Multi-Area Terminals will beep on
warning functions from all Areas.
2.3 LAMP INDICATIONS.
* Alarm indication takes priority over Isolate or other indication.
^ See “System Inputs” on page 72 in the Tables section.
Lamp
ON
OFF
FLASHING
ZONE Lamps
1 to 16
When the Zone
is Unsealed.
(If the "Zone activity"
option is enabled)
When the Zone
is Sealed.
FAST: * When there has been an
Alarm / Tamper on the Zone.
SLOW: * When the Zone has been Isolated.
AREA Lamps
A1, A2, A3, A4
Area is Armed.
(Multi-Area mode
only)
Area is Dis-armed.
Note: Multi-Area mode only.
FAST: * There has been an Alarm in the Area.
SLOW: * Area Armed in Home Mode.
ARM
Area/s are armed
in Away mode.
System not armed
in Away mode.
There has been an alarm in an Area armed in
Away mode.
HOME
Area/s are armed
in Home mode.
System not armed
in Home mode.
There has been an alarm in an Area armed in
Home mode.
FAULT ^
A system input is
currently in alarm. ^
No system inputs
are in alarm.
SLOW:
When a System Input has been Isolated. ^
PWR
AC mains OK
AC mains problem.
-
ARM & HOME
-
-
System is in "Master Operations" mode.
i.e. NEXT functions.
ARM, HOME &
FAULT.
-
-
System is in "User Programming" mode.
ARM, HOME,
FAULT & PWR
-
-
System is in "Installer Programming" mode.
0
Used to display values in programming mode.