2.4 ACCESS CONTROL AND THE IQ PLUS.
REQUIRED EQUIPMENT.
Enhanced Access Terminal V2.01 or greater; Door strike; Relay board for door strike;
Wiegand reader. The Terminal installation document 635500EN contains additional informa-
tion on installation.
DOOR OPTIONS.
The Door (door strike and door reed switch) connected to the Terminal is automatically
associated with that Terminal and can be referred to by the Terminal number, for example;
Terminal 1 = door 1. Terminals can be associated to areas and will only display zone activity
for that Area. (Address 561-564)
All doors will use the same global lock open time (time the door strike is activated) as
programmed at address 909 - Terminal Auxiliary time. This must be programmed to a value
other than 0 for the door to remain open following a valid request to open.
If a 0 is left at
this location the lock will open but close again almost immediately, i.e. remain locked.
Valid entries are from 0 to 255 seconds. (Factory default 5 Seconds).
REQUEST TO EXIT BUTTON.
A “Request to Exit” (REX), is typically a button provided to unlock a door from the inside
either bypassing the need to use a reader during low security periods, or because an internal
(exit) reader is not required. The “REX” device can also be a PIR or Photo-Electric beam to
detect the User approaching the door.
If a REX button is fitted it will activate the door for the
lock open time (see above). The REX operation is enabled regardless of the state of the
associated Area and is entered into Access Review.
The OFF key can also be used as a REX button if it is programmed at address 918.
ADDING A CARD AND USER PIN.
Once fitted and tested, learning the card (entering the card details into the panel) is done
exactly the same as adding a User PIN with the exception that the card is also presented
(explained in detail in section 7, the Basic Programming Guide).
A User can have both a PIN and card, accessing the door using either method. A reader
need not be fitted if PIN only access is required. The door will open for lock open time
following a valid PIN + OFF key.
For higher security applications, both PIN and card can be required to open the door.
This option is global and is set at Address 919.
Each door will assume Area control of the Area associated with the Terminal, a Terminal
MUST be associated with an Area.
The following rules apply:
1) If the User is assigned to an Area that is also associated to the Terminal,
(a)If the Area is armed, badging a card will disarm the associated Area and open the door.
(The event is entered into Access Review).
(b) If the Area is disarmed, badging a card will open the door. (The event is entered into
Access Review)
2) If the User is not assigned to the Area associated to the Terminal,
(a) If the Area is armed, badging a card will not open the door (The event is entered into
Access Review).
(b) If the Area is disarmed, badging a card will open the door (The event is entered into
Access Review).
DOOR FORCED
A Door Forced condition is activated when the reed switch goes into alarm without a valid
request to open the door, this also causes the Door Forced system input to go into alarm.
(The event is entered into Access Review)
An Auxiliary can be used to indicate this system input by setting the Auxiliary type; 131
(door1)-138 (door 8) as described in the Tables-Section 10. This Auxiliary will pulse on for
500ms every 5 seconds till cleared. Door Forced is an Alarm condition and is cleared by
using a valid PIN+OFF key.
DOTL
A DOTL (Door open too long) condition is activated when the door is open for longer than a
period of time equal to 4 times that of the lock open time set at Address 909. This means
that once a valid request to open occurs, the lock timer starts and so does the DOTL timer.
Causing the DOTL system input to go into alarm. (The event is entered into Access Review)
An Auxiliary can be used to indicate this system input by setting the Auxiliary type;
141(door 1)-148 (door 8) as described in the Tables-Section 10. This Auxiliary will pulse on
for 500ms every 5 seconds till cleared. DOTL is a warning condition and is cleared by
using a valid PIN + OFF key or a valid card badge.