CONCEPT IQ. PLUS Programmer’s Manual.
A wide range of Auxiliary Event Types are available. Full details are found in the Tables section on page 71-73.
IMPORTANT NOTE: Auxiliary Event Types; 7 -Smoke Detector Reset, 13 & 14 -User Auxiliary A & B, 15 -Day Alarm, 17 -RF Auxiliary and
21 to 36 -Zone 1 to 16 in Alarm can only be turned off by an Auxiliary Timer or from the Auxiliary Control and Test Menu. (NEXT 24).
It is therefore recommended that these Event Types should also have an Auxiliary Action assigned that incorporates a timer (i.e. Auxiliary
Actions 2 to 13) and a suitable Auxiliary Timer value programmed.
Common Auxiliary Event Types:
1
Burglary Alarm. (Strobe)
3
Zone Bypass on Arming.
9
Follow Ext. Siren
11
EntryTimer (Any Area)
2
Fire Alarm.
4
System Alarm.
10
Follow Int. Siren
12
Exit Timer (Any Area)
131
Door Forced or DOTL Alarm on Door One
141
DOTL Alarm on Door One
AUXILIARY TIMER VALUE
These Addresses allow a Timer Value to be programmed for any Auxiliary Actions that incorporate a Timer.
(Auxiliary Actions 2 to 13)
The Timer Value will be in Seconds or Minutes depending on which is specified in the Auxiliary Action. (If a timer value of 1 to 4 Minutes is
required, program the timer in Seconds)
Programming Addresses for Auxiliary Timer programming:
AUXILIARY ACTION
15 Auxiliary Actions are available. Full details of all Auxiliary Actions are found in the Tables section on page 74.
Common Auxiliary Actions:
0
Follow Event Status.
2
One Shot Timed in Seconds.
1
Invert Event Status.
4
One Shot Timed in Minutes.
Programming Addresses for Auxiliary Action programming:
Spare
(Value Data)
Spare
(Value Data)
0 - Follow Event
Status
811-829
830-840
841-859
860-870
ADDRESS
DEFAULT
FUNCTION
(Data Type)
Auxiliary
0
1
2
3
4
5
6
7
8
9
10
Address
860
861
862
863
864
865
866
867
868
869
870
Auxiliary
0
1
2
3
4
5
6
7
8
9
10
Address
830
831
832
833
834
835
836
837
838
839
840