p80
Ver. 3.003 (24/4/03)
CONCEPT IQ. PLUS Programmer’s Manual.
Each event in Contact ID is sent as a string of 16 DTMF digits. For example, an alarm followed by a restore and then an opening would be 3 events. All Contact ID strings follow the format:
CCCC 18 SXYZ GG PPP K where:
CCCC
4 digit client code that identifies the panel or site.
18
Always the digits “18”.
SXYZ
Event code.
S = Status. 1 - Alarm or Opening. 3 - Restore or Closing. (Note: Alarm Restores only reported on Area Opening)
XYZ = Type of Event.
GG
Group Byte which signifies the Area being Opened/Closed or the Area in which the alarm occurred.
PPP
Point ID. This refers to either the Point number or the User ID depending on the type of event.
K
Checksum.
Some receivers display a “U” (User) or a “C” (Alarm Point) in front of the PPP, depending on which of these PPP represents.
TYPE OF ALARM MESSAGE
EVENT
CODE
GROUP BYTE
(AREA)
POINT ID
Zone Type (Zone Inputs)
XYZ
GG
PPP
0 - Instant (Burglary)
130
01 to 04
001 to 016
1 - Delayed (Entry/Exit)
130
01 to 04
001 to 016
2 - Handover
130
01 to 04
001 to 016
3 - 24hr Burglary
130
01 to 04
001 to 016
4 - 24hr Fire
110
01 to 04
001 to 016
5 - 24hr Panic
120
01 to 04
001 to 016
6 - 24hr Duress
121
01 to 04
001 to 016
Tamper
144
01 to 04
001 to 016
Isolate
570
01 to 04
001 to 016
System Inputs
^ = Restore not reported.
AC Fail (Mains power trouble)
301
00
101
Low Battery
302
00
102
Cabinet Tamper (Expander Mod. Tamper)
145
00
103
Siren Monitor Alarm
320
00
104
LAN Fuse fail
140
00
105
Battery Fuse fail
140
00
106
Comms Fail
354
00
107 ^
System Reset
305
00
108 ^
TYPE OF ALARM MESSAGE
EVENT
CODE
GROUP BYTE
(AREA)
POINT ID
Keypad Lockout
140
00
109 ^
Zone Self Test Fail
307
00
110 ^
Keypad Medical Alarm (Personal Emerg.)
100
00
111 ^
Keypad Panic Alarm
120
00
112 ^
Keypad Duress Alarm
121
00
113 ^
Keypad Fire Alarm
110
00
114 ^
Spare
-
00
115 ^
Spare
-
00
116 ^
Spare
-
00
117 ^
Spare
-
00
118 ^
Spare
-
00
119 ^
Test Report (Periodic)
602
00
120 ^
System Input Isolate
570
00
101 to 120
Open / Close
By User PIN code - Single Area
401
01 to 04
001 to 047
By User PIN code - General Open/Close
402
00
001 to 047
By System* - Single Area
403
01 to 04
48
By System* - General Open/Close
402
00
48
Quick Arm
408
01 to 04
48