p18
Ver. 3.003 (24/4/03)
CONCEPT IQ. PLUS Programmer’s Manual.
7. BASIC PROGRAMMING GUIDE.
1 ZONE TO 16 ZONE BURGLARY ALARM SYSTEM.
The Programming Sequence beginning on the following page takes the Installer through the steps required to program a typical Burglary Alarm System.
Programming options for Multi-Area systems, Access Control and Off-site reporting are included.
In many cases system programming can be completed by following these steps.
Where more advanced programming is required, follow this Basic Programming Guide first, then refer to the programming procedures found in Section 8 -
”Programming of Advanced Features” .
IMPORTANT NOTES:
1)
It is highly recommended that the system is fully defaulted to the factory presets as described in Step 1 before the rest of the programming sequence is performed.
2)
In the database fields described, only the options relevant to basic system programming are shown.
In many cases other options are available. Simply ignore any options not listed. These are not relevant to basic programming and are explained in the appropriate
applications in Section 8 -”Programming Advanced Features”.
3)
Section 9 -”Programming Reference” can be referred to for extra details on any option when required.
INSTALLATION NOTES:
1)
If Siren and Strobe are to be used, it is recommended that:
•
An 8 Ohm Siren Speaker is connected between “DET+” and “SPK” on connector T5 as shown in the Installation guide. (Aux 0)
•
A 12V Strobe is connected as follows: to “DET+”, Strobe - to “OUT 1” on connector T5 as shown in the Installation guide. (Aux 1)
If you prefer to progam the system by following the Address locations in numerical order, go to Section 9 -”Programming Reference”
How to Enter Data.
Select Address: Key in the Installer PIN Code; Press
then enter the 3 digit Address
(A1 to A3 Lamps will flash to prompt for each digit). The current Data will be displayed.
Enter Data:
Enter the new Data
.. (1-16 digits) OR Option/s to Select/De-select
, then
. NOTE:
clears the current field of all data or settings ready for new data.