background image

 

 

 

Astra-642  

 

Ultrasonic

 

Volumetric Detector 

 

Operating Manual 

 

 

 

 

 

 

 

 

Rev. 642-v2_6_en                                                                                   

 1

 

The  operating  manual  describes  the  operating  principle,  opera-
tional  and  maintenance  conditions  pertaining  to  ultrasonic  volu-
metric detector Astra-642 (

hereinafter “detector”) (Fig.1). 

The  manufacturer  reserves  the  right  to  introduce  changes 
which  update  and  retrofit  the  detector  without  prior  notice.  All 
such  changes  will  be  described  in  an  updated  revision  of  the 
operating manual. 

 

1  Function 

 

The  detector  detects  intrusion  into  a  pro-
tected volume of a closed room and gene-
rates  an  alarm  notification  by  opening  out-
put contacts of the signaling relay. 

 

The  detector  is  powered  by  any  DC 
source with rated voltage of 12V and pul-
sation amplitude not exceeding 0.1V. 

 

2  Operating Principle 

 

2.1

 The operating principle of 

the ultrasonic channel (herei-
nafter  referred  to  as  the  US-
channel)  is  based  on  the 
Doppler  Effect 

–  changes  in 

frequency 

of 

ultrasonic 

waves  emitted  by  the  detec-
tor,  when  they  are  reflected 
from a moving object.    
An  electric  signal  from  the  ul-
trasonic  sensor  is  sent  to  a 
microcontroller, which 

– if sig-

nals are present in both chan-
nels and in accordance with a 
present  operation  algorithm 

– 

generates the “Alarm” notifica-
tion by opening the output cir-
cuit of the optic-electronic relay. 

 

2.2

 Schematics of the detec-

tion zone are shown in Fig. 2. 

 

Note

 

–  The  US-channel  de-

tection  zone  depends  on  a 
specific  room:  some  objects 
absorb  or  reflect  ultrasound, 
thus  distorting  the  detection 
zone.  

 

3  Specifications 

 

Technical Parameters of US-channel  

Intrusion detection range, m, min................................................... 10 
Confident detection area angle  
in horizontal and vertical plane, 

о

 ............................................ 90 

Operating frequency, kHz ....................................................... 25 
Movement speed detection range, m/s................ from 0.3 to 2.0 
Recommended mounting height, m ....................................... 2.2 

General Technical Parameters

 

Power supply voltage, V .......................................... from 8 to 15 
Current consumption, mA, max .............................................. 25 
Readiness time, s, max .......................................................... 20 
Permissible current through relay contacts, А, max............. 0,08 
Permissible voltage on relay contacts, V, max ..................... 100 
Resistance of the circuit, included in the alarm loop  
in standby mode, Ohm ........................................................... 16 
Overall dimensions, mm, max ............................... 106.

5×72×38 

Weight, kg, max ................................................................... 0.08

 

Operating Conditions 

Temperature range, 

°

С ................................. from -10 up to +50  

Relative air humidity, %  ...................................... up to 95 at + 35 

°

С 

no moisture condensation 

 

4  Delivery Set 

 

Ultrasonic volumetric detector Astra-642 ........................... 1 pcs. 
Bracket ............................................................................... 1 pcs. 
Screw 

2,9х25 (or 2-3x30) ................................................... 2 pcs. 

Dowel 

5х25 ........................................................................ 2 pcs. 

Sealing material ................................................................. 1 pcs. 
User Instruction ................................................................ 1 copy. 

 

5  Structure 

 

 

 

Fig. 3 

 

Structurally,  the  detector  is  a  unit  comprised  of  a  base  and  a 
removable cover.  

 

The  unit  houses  a  printed  circuit  board  with  radio  elements, 
screw  terminal  blocks  for  external  connections,  ultrasonic 
transmitter and receiver (Fig. 3).  

 

A  switch  installed  on  the  printed  circuit  board  generates  a 
“Tampering”  notification when the cover is detached by open-
ing the ТМР circuit (irrespective of whether or not the detector 
power supply is switched on).  

 

The  following  indicators  are  mounted  on  the  printed  circuit 
board:  red 

–  for  detector status  monitoring,  blue  –  for  interfe-

rence indication. 

 

The  US-channel  detection  range  can  be  adjusted  using  the 
US-channel range controller. 

 

Fig. 1 

Fig. 2 

Side view

 

Top view

 

Confident detection area

 

Probable detection area

 

10m

 

2.2m

 

10m

 

6m 

 
 
 

 

 

 
 

 

 

6m 

Wire 
insertion holes

 

Mounting 
holes

 

Screw  
terminals 

Tamper 
Switch

 

 
PCB

 

Ultrasonic 
transmitter

 

Plugs

 

Jumpers

 

US-channel 
range  
controller

 

Indicators

 

Ultrasonic 
transmitter

 

Base

 

Cover removed

 

Отзывы: