Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
815-100
815
The floating-point processor test failed. Go to “Performing the checkout procedure”
on page 187.
815-101
815
Floating point processor failed. Go to “Performing the checkout procedure” on page
187.
815-102
815
Floating point processor failed. Go to “Performing the checkout procedure” on page
187.
815-200
815 7C0
Power-on self-test indicates a processor failure. Go to “Performing the checkout
procedure” on page 187.
815-201
815
Processor has a status of failed. A processor with a failed status is deconfigured and
therefore cannot be tested or used by the system. Go to “Performing the checkout
procedure” on page 187.
817-123
817
The I/O planar time-of-day clock test failed. Go to “Performing the checkout
procedure” on page 187.
817-124
817
Time of day RAM test failed. Go to “Performing the checkout procedure” on page
187.
817-210
817
The time-of-day clock is at POR. Go to “Performing the checkout procedure” on
page 187.
817-211
817
Time of day POR test failed. Go to “Performing the checkout procedure” on page
187.
817-212
151
The battery is low. Go to “Performing the checkout procedure” on page 187.
817-213
817
The real-time clock is not running. Go to “Performing the checkout procedure” on
page 187.
817-215
817
Time of day clock not running test failed. Go to “Performing the checkout
procedure” on page 187.
817-217
817
Time of day clock not running. Go to “Performing the checkout procedure” on page
187.
887-101
887
POS register test failed. Go to “Performing the checkout procedure” on page 187.
887-102
I/O register test failed. Go to “Performing the checkout procedure” on page 187.
887-103
887
Local RAM test failed. Go to “Performing the checkout procedure” on page 187.
887-104
887
Vital Product Data (VPD) failed. Go to “Performing the checkout procedure” on page
187.
887-105
887
LAN coprocessor internal tests failed. Go to “Performing the checkout procedure” on
page 187.
887-106
887
Internal loopback test failed. Go to “Performing the checkout procedure” on page
187.
887-107
887
External loopback test failed. Go to “Performing the checkout procedure” on page
187.
887-108
887
External loopback test failed. Go to “Performing the checkout procedure” on page
187.
887-109
887
External loopback parity tests failed. Go to “Performing the checkout procedure” on
page 187.
887-110
887
External loopback fairness test failed. Go to “Performing the checkout procedure” on
page 187.
887-111
887
External loopback fairness and parity tests failed. Go to “Performing the checkout
procedure” on page 187.
887-112
887
External loopback (twisted pair) test failed. Go to “Performing the checkout
procedure” on page 187.
Chapter 2. Diagnostics
151
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...