Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
651-66A
2CE
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 187.
651-66B
2CC
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 187.
651-674
302
Failed memory module. Go to “Performing the checkout procedure” on page 187.
651-675
303
Failed memory module. Go to “Performing the checkout procedure” on page 187.
651-676
304
Failed memory module. Go to “Performing the checkout procedure” on page 187.
651-679
2CD
Failed memory module. Go to “Performing the checkout procedure” on page 187.
651-67A
2CE
Failed memory module. Go to “Performing the checkout procedure” on page 187.
651-67B
2CC
Failed memory module. Go to “Performing the checkout procedure” on page 187.
651-685
303
Memory module has no matched pair. The most probable failure is the memory
module paired with the memory module identified by the location code. Go to
“Performing the checkout procedure” on page 187.
651-686
304
Memory module has no matched pair. The most probable failure is the memory
module paired with the memory module identified by the location code. Go to
“Performing the checkout procedure” on page 187.
651-710
214 2C4
System bus parity error. Go to “Performing the checkout procedure” on page 187.
651-711
210 2C4
System bus parity error. Go to “Performing the checkout procedure” on page 187.
651-712
214
System bus parity error. Go to “Performing the checkout procedure” on page 187.
651-713
214
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 187.
651-714
2C4
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 187.
651-715
2C4
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 187.
651-720
2C7 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-721
2C6 2C7 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page
651-722
2C4
System bus parity error. Go to “Performing the checkout procedure” on page 187.
651-723
2C4
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 187.
651-724
292
I/O host bridge time-out error. Go to “Performing the checkout procedure” on page
187.
651-725
292
I/O host bridge address/data parity error. Go to “Performing the checkout
procedure” on page 187.
651-726
Software
I/O host bridge timeout caused by software. This error is caused by a software or
operating system attempt to access an invalid memory address. Go to “Performing
the checkout procedure” on page 187.
651-731
2C8
Intermediate or system bus address parity error. Go to “Performing the checkout
procedure” on page 187.
651-732
2C8
Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 187.
651-733
2C8
Intermediate or system bus address parity error. Go to “Performing the checkout
procedure” on page 187.
146
JS12 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...