Table 12. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
3084
A problem occurred during the
startup of a partition.
The adapter type might not be
supported.
Verify that the adapter type is supported.
3088
Informational system log entry only.
No corrective action is required.
308C
A problem occurred during the
startup of a partition.
The adapter type cannot be
determined.
Verify that a valid I/O Load Source is tagged.
3090
A problem occurred during the
startup of a partition.
Go to “Isolating firmware problems” on page 222.
3110
A problem occurred during the
startup of a partition.
Go to “Isolating firmware problems” on page 222.
3113
A problem occurred during the
startup of a partition.
Look for B7xx xxxx errors and resolve them.
3114
A problem occurred during the
startup of a partition.
Look for other errors and resolve them.
3120
Informational system log entry only.
No corrective action is required.
3123
Informational system log entry only.
No corrective action is required.
3125
During the startup of a partition, the
blade server firmware could not
obtain a segment of main storage
within the blade server to use for
managing the creation of a partition.
Check for server firmware updates; then, install the
updates if available.
3128
A problem occurred during the
startup of a partition. A return code
for an unexpected failure was
returned when attempting to query
the load source path.
Look for and resolve B700 69xx errors.
3130
A problem occurred during the
startup of a partition.
Check for server firmware updates; then, install the
updates if available.
3135
A problem occurred during the
startup of a partition.
Check for server firmware updates; then, install the
updates if available.
3140
A problem occurred during the
startup of a partition. This is a
configuration problem in the
partition.
Reconfigure the partition to include the intended load
source path.
3141
Informational system log entry only.
No corrective action is required.
3142
Informational system log entry only.
No corrective action is required.
3143
Informational system log entry only.
No corrective action is required.
3144
Informational system log entry only.
No corrective action is required.
3145
Informational system log entry only.
No corrective action is required.
Chapter 2. Diagnostics
33
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...