v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Isolation
Procedure Code
Symptom
Action
FSPSP09
A problem has been
detected with a
memory DIMM, but
it cannot be isolated
to a specific memory
DIMM.
Replace the CRU called out after this FSPSP call. If the CRU that is
called out is a DIMM CRU, perform the following procedure:
1.
Replace both memory DIMMs of the pair on the microprocessor that
contains the failing CRU:
DIMM 1 (P1-C4)
Replace DIMMS 1 and 2.
DIMM 2 (P1-C3)
Replace DIMMS 1 and 2.
DIMM 3 (P1-C1)
Replace DIMMS 3 and 4.
DIMM 4 (P1-C2)
Replace DIMMS 3 and 4.
2.
See “Removing a memory module” on page 251 for location
information and the removal procedure.
3.
Install new memory DIMMs, as described in “Installing a memory
module” on page 251.
See “Supported DIMMs” on page 4 for more information.
FSPSP10
The part indicated in
the CRU callout that
follows this
procedure is invalid
or missing for this
system’s
configuration.
1.
If there is only one CRU called out after this FSPSP10 call:
a.
Verify that the CRU is installed, connected, and seated properly.
b.
If the CRU is seated properly and the problem persists, replace
the CRU.
c.
If the CRU is missing, add the CRU.
2.
If multiple CRUs are called out, they have identical serial numbers.
Remove all but one of the CRUs.
FSPSP11
The service processor
has detected an error
on the RIO/HSL port
in the system unit.
1.
Verify that the operating system is running. If it is running, perform
an in-band firmware update, as described in “Updating the
firmware” on page 277.
2.
If the problem persists, replace the system board and chassis
assembly, as described in “Replacing the Tier 2 system-board and
chassis assembly” on page 274.
FSPSP12
The DIMM CRU that
was called out failed
to correct the
memory error.
Replace the system board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on page 274.
Chapter 2. Diagnostics
209
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...