Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
252B-718
252B 293
Temporary PCI bus error detected by adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
252B-719
252B
Device bus termination power lost or not detected.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
252B-720
252B
Adapter detected device bus failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
252B-721
252B
Temporary adapter detected device bus failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
252B-722
252B
Device bus interface problem.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
252B-723
252B
Device bus interface problem.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
254E-201
254E 221
Adapter configuration error. Go to “Performing the checkout procedure” on page
187.
254E-601
254
Error log analysis indicates adapter failure. Go to “Performing the checkout
procedure” on page 187.
254E-602
254
Error log analysis indicates an error attention condition. Go to “Performing the
checkout procedure” on page 187.
254E-603
254
Error log analysis indicates that the microcode could not be loaded on the adapter.
Go to “Performing the checkout procedure” on page 187.
254E-604
254
Error log analysis indicates a permanent adapter failure. Go to “Performing the
checkout procedure” on page 187.
254E-605
254
Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to “Performing the checkout procedure” on page 187.
254E-606
254
Error log analysis indicates adapter failure. Go to “Performing the checkout
procedure” on page 187.
254E-701
254E 221
Error log analysis indicates permanent adapter failure. Go to “Performing the
checkout procedure” on page 187.
154
JS12 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...