Table 5. 1xxxyyyy SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Error Codes
Description
Action
2633
1.2V reg_pgood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2640
VRM CP1 core pGood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2642
VRM CP1 cache pGood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2643
1.2V power good signal fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2647
No 12V dc coming to the
blade server from the
BladeCenter midplane
1.
Check the management-module event log for errors that
indicate a power problem with the BladeCenter.
2.
Resolve any problems that are found.
3.
Reboot the blade server.
4.
If the problem is not resolved, replace the system-board and
chassis assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page 274.
2648
Blade power latch fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2649
Blade power fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2670
The BladeCenter encountered
a problem, and the blade
server was automatically shut
down as a result
1.
Check the management-module event log for entries that were
made around the time that the JS12 blade server shut down.
2.
Resolve any problems that are found.
3.
Reboot the blade server.
4.
If the problem is not resolved, replace the system-board and
chassis assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page 274.
2671
12V power fault in the blade
server
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
20
JS12 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...