Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
256D-702
256D 221
Error Log Analysis indicates permanent adapter failure is reported on the other port
of this adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board and chassis assembly.
25A0–xxx
2631
Configuring I/O planar control logic for IDE bus devices. Go to “Performing the
checkout procedure” on page 187.
25C4–xxx
25C4
Generic reference for Broadcom adapter. Go to “Performing the checkout procedure”
on page 187.
25C4-201
25C4
Configuration error. Go to “Performing the checkout procedure” on page 187.
25C4-701
25C4
Permanent adapter failure. Go to “Performing the checkout procedure” on page 187.
25C4-601
25C4
Download firmware error. Go to “Performing the checkout procedure” on page 187.
25C4-602
25C4
EEPROM read error. Go to “Performing the checkout procedure” on page 187.
2604-xxx
2604
Generic reference for 4Gb Fibre Channel PCI-X Adapter card. Go to “Performing the
checkout procedure” on page 187.
2604-102
2604
Reset Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre Channel
PCI-X Adapter card.
2604-103
2604
Register Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel PCI-X Adapter card.
2604-104
2604
SRAM Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel PCI-X Adapter card.
2604-105
2604
Internal Wrap Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel PCI-X Adapter card.
2604-106
2604
Gigabit Link Module (GLM) Wrap Test failure for the Fibre Channel adapter card.
Replace the 4Gb Fibre Channel PCI-X Adapter card.
2604-108
2604 221
Enhanced Error Handling Failure on the bus for the Fibre Channel adapter card. Go
to “Performing the checkout procedure” on page 187.
2604-110
2604
Enhanced Error Handling Failure on the Fibre Channel adapter card. Replace the
4Gb Fibre Channel PCI-X Adapter card.
2604-201
2604 221
Configuration Register Test Failure for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 187.
2604-203
2604
PCI Wrap Test Failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel PCI-X Adapter card.
2604-204
2604 221
DMA Test Failure for the Fibre Channel adapter card. Go to “Performing the
checkout procedure” on page 187.
2604-205
2604 221
Error on Read/Write Operation for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 187.
2604-701
2604
Error Log Analysis indicates that the adapter self-test failed for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 187.
2604-703
2604
Error Log Analysis indicates that an unknown adapter error has occurred for the
Fibre Channel adapter card. Go to “Performing the checkout procedure” on page
187.
2604-704
2604
Error Log Analysis indicates that an adapter error has occurred for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 187.
156
JS12 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...