Table 13. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
0601
Informational system log entry only.
No corrective action is required.
Note:
This code and associated data can be
used to determine why the time of day for a
partition was lost.
0602
System firmware detected an error
condition.
1.
Collect the event log information.
2.
Go to “Isolating firmware problems” on
page 222.
0611
There is a problem with the system
hardware clock; the clock time is
invalid.
Use the operating system to set the system
clock.
0621
Informational system log entry only.
No corrective action is required.
0641
System firmware detected an error.
1.
Collect the platform dump information.
2.
Go to “Isolating firmware problems” on
page 222.
0650
System firmware detected an error.
Resource management was unable to
allocate main storage. A platform dump
was initiated.
1.
Collect the event log.
2.
Collect the platform dump data.
3.
Collect the partition configuration
information.
4.
Go to “Isolating firmware problems” on
page 222.
0651
The system detected an error in the
system clock hardware
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
274.
0803
Informational system log entry only.
No corrective action is required.
0804
Informational system log entry only.
No corrective action is required.
0A00
Informational system log entry only.
No corrective action is required.
0A01
Informational system log entry only.
No corrective action is required.
0A10
Informational system log entry only.
No corrective action is required.
1150
Informational system log entry only.
No corrective action is required.
1151
Informational system log entry only.
No corrective action is required.
1152
Informational system log entry only.
No corrective action is required.
1160
Service processor failure
1.
Go to “Isolating firmware problems” on
page 222.
2.
Replace the system-board and chassis
assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly”
on page 274.
1161
Informational system log entry only.
No corrective action is required.
Chapter 2. Diagnostics
41
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...