Table 12. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
1141
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
1142
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
1143
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
1144
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
1148
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
1150
During the startup of a partition, a
partitioning configuration problem
occurred.
Go to “Verifying the partition configuration” on page 189.
1151
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
1170
During the startup of a partition, a
failure occurred due to a validation
error.
Go to “Verifying the partition configuration” on page 189.
1225
A problem occurred during the
startup of a partition.
The partition attempted to start up
prior to the platform fully
initializing. Restart the partition after
the platform has fully completed and
the platform is not in standby mode.
Restart the partition.
1230
During the startup of a partition, a
partitioning configuration problem
occurred; the partition is lacking the
necessary resources to start up.
Go to “Verifying the partition configuration” on page 189.
30
JS12 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...