Table 32. Light path diagnostic LED descriptions (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path
diagnostics LED
Description
Action
DIMM x error
P1-C1 DIMM 1
P1-C2 DIMM 2
P1-C3 DIMM 3
P1-C4 DIMM 4
P1-C5 DIMM 5
P1-C6 DIMM 6
P1-C7 DIMM 7
P1-C8 DIMM 8
A memory error occurred.
1.
Verify that the DIMM indicated by the lit
LED is a supported memory module, as
described on the ServerProven Web site.
2.
Reseat the DIMM indicated by the lit LED,
as described in “Installing a memory
module” on page 251.
3.
Replace the DIMM indicated by the lit
LED, as described in “Removing a memory
module” on page 251 and “Installing a
memory module” on page 251.
Note:
Multiple DIMM LEDs do not
necessarily indicate multiple DIMM failures. If
more than one DIMM LED is lit, reseat or
replace one DIMM at a time until the error
goes away. See the online information or the
Hardware Maintenance Manual and
Troubleshooting Guide
or
Problem Determination
and Service Guide
for your BladeCenter unit for
further isolation.
Hard disk drive
error
P1-D1 SAS 0
(front)
P1-D2 (SAS 1 (rear)
A hard disk drive error occurred.
1.
Reseat the hard disk drive, as described in
“Installing a SAS hard disk drive” on page
249.
2.
Replace the hard disk drive, as described
in “Removing a SAS hard disk drive” on
page 248 and “Installing a SAS hard disk
drive” on page 249.
PCIe high speed
expansion card
error
P1-C11 PIOCARD
An I/O expansion card option error occurred.
1.
Make sure that the I/O expansion option is
supported.
2.
Reseat the I/O expansion option, as
described in “Removing and installing an
I/O expansion card” on page 260.
3.
Replace the I/O expansion option.
220
JS12 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...