background image

www.wegener.com 

   800092-02 Rev. C  

 

 

General Information 

The 

WEGENER iPump 562

 is a digital media server capable of decoding satellite signals or IP streams or playing stored 

content from its internal hard disk drive.  

Features 

 

 

Supports DVB-S QPSK, DVB-S2 QPSK, and DVB-S2 8PSK symbol modulation formats 

 

 

Supports decoding MPEG-2 and MPEG-4/H.264 compression 

 

 

Supports PAL and NTSC standard definition video output  formats via composite video outputs 

 

 

Supports 720p and 1080i high definition video output formats via HDMI and YPbPr component outputs 

 

 

Plays single transport stream files or playlists 

 

 

Supports Wegener’s Compel control system via RF or IP 

 

 

Supports Wegener’s conditional access system 

 

 

Supports DVB sub-titling and teletext services 

 

 

Supports Digital Signage 

 

 

Supports decoding/rendering of closed captioning or passthru to TV for decode 

 

 

Receives file downloads via Compel Assured File Delivery system 

 

 

Decodes IP multicast and unicast streams 

 

 

Two relay outputs, both can be user controllable or one assigned to alarms 

 

 

One GPIO input used for triggered playback of files/playlists 

 

 

RS232 serial port that can be assigned to terminal mode or printer mode 

 

 

SNMP monitoring 

 

 

S/PDIF digital audio output, linear PCM or bitstream 

 

 

Optional IR remote control 

 

Compel™ Network Control 

Compel

 

gives you the power to manage a network of iPump562’s and other Unity IRDs with unparalleled functionality. With its 

unique network management features, such as grouping, receiver control and scheduling, the operator can command 
individual groups of receivers to switch, tune, or "output" video or data targeted specifically for that one receiver or group of 
receivers. This ability can be utilized for unequalled disaster recovery for business critical operations.  

iPump 562

Digital Media Server

User’s Manual

Содержание iPump 562

Страница 1: ... of closed captioning or passthru to TV for decode Receives file downloads via Compel Assured File Delivery system Decodes IP multicast and unicast streams Two relay outputs both can be user controllable or one assigned to alarms One GPIO input used for triggered playback of files playlists RS232 serial port that can be assigned to terminal mode or printer mode SNMP monitoring S PDIF digital audio...

Страница 2: ...240VAC 50 60Hz 1 5A Rear Panel Connections iPump 562 rear panel view iPump 562 Rear Panel Connections Signal Connector Description DC IN Male Power Jack 12 VDC 5A RF IN Port 1 Type F 950 to 2150 MHz signal accepted LNB power and Universal Astra signaling available RF IN Port 2 3 4 Type F Optional 950 to 2150 MHz signal accepted RS232 Port RJ 12 Serial Asynchronous Data May be used for terminal or ...

Страница 3: ...pinout connections for the RJ 12 and DB 9 connector Serial Port RS 232 Pinouts Image Pin Input Output Description Pin Input Output Description 1 No Connection 4 No Connection 2 TX Data Output 5 Ground 3 RX Data Input 6 5V DC GPIO Pinouts Image Pin Input Output Description Pin Input Output Description 1 Alarm relay Common 6 Alarm relay Normally Closed 2 Alarm relay Normally Open 7 User relay Normal...

Страница 4: ...lashing amber for warning LED Indications The iPump562 supplies an operational status using the LED A steady Green LED indicates that there are no warning or alarm conditions The LED will flash when receiving commands from Compel or when downloading files If there is a problem the LED flashes Red for alarm conditions or Amber for warning conditions In general alarms indicate that the unit cannot p...

Страница 5: ... activate the OSD You may use the push buttons to navigate through the menus displayed to view the existing settings OSD Menus The OSD information displays white text on a blue background overlaid on the video output from the iPump 562 View the OSD from a monitor connected to any of the video output ports of the iPump 562 server Navigating OSD Menus Use the arrow and Enter buttons on the iPump 562...

Страница 6: ...y be changed by scrolling through the list of available audio s using the up down keys If the unit is currently decoding a LAN Ethernet stream this will not be in the menu and the unit will decode the first audio in the stream Audio 2 Language Displays the current audio program descriptor or which means the first available audio for the Audio 2 output It may be changed by scrolling through the lis...

Страница 7: ...ean that sound effects doors closing background noises etc are included for the hearing impaired What is actually displayed is dependent upon the data transmitted Subtitling cannot be enabled if closed captioning is set to anything other than PASSTHRU in the decoder setup menu Language Allows selection of the subtitling language when subtitling is enabled The languages listed are those received in...

Страница 8: ...urrent Channel Allows editing of RF tuning parameters frequency data rate FEC rate program number etc DVB S2 Alpha Adjusts the receiver RF filter characteristics Options are 20 25 and 35 This setting only applies to DVB S2 symbol modulated RF carriers LNB Setup Allows editing of LNB type and frequency LNB DC Power Allows enabling or disabling of LNB power insertion on RF port 1 The voltage is nomi...

Страница 9: ... Modulation FEC Rate Eb No Alarm Level 1 2 4 50 2 3 5 00 DVB S QPSK 3 4 5 50 5 6 6 00 7 8 6 40 1 2 1 03 3 5 1 46 DVB S2 QPSK 2 3 1 87 3 4 2 29 4 5 2 65 5 6 2 97 7 8 3 71 9 10 3 88 3 5 2 96 2 3 3 63 DVB S2 8PSK 3 4 4 40 5 6 5 38 8 9 6 44 9 10 6 68 Signal Quality Setup Allows editing of the number of errored seconds per minute at which to display an alarm Signal Strength Meter Displays a meter showi...

Страница 10: ...t upon modulation selected Frequency Allows editing of the RF carrier frequency This frequency value must be a valid value based on the LNB LO setting C band KU band etc The LNB LO frequency should be correctly set before setting this value The iPump562 receives L band frequencies in the range of 950 MHz to 2150 MHz The LNB will down convert the actual transmitted RF carrier frequency to L band Th...

Страница 11: ...22 KHz tone in accordance with the ASTRA standard where the presence of the 22 KHz tone will select Euro High KU band 11 70 12 75 GHz and its absence will select Euro Low KU band 10 70 11 70 GHz The voltage will select the polarity 13Vdc vertical 18Vdc horizontal LO Type Allows selection of the LO type when the LNB type is Local Oscillator The choices are Custom Freq which allows entry of frequenc...

Страница 12: ... versus the tuned carrier frequency Signal Strength Meter The Signal Strength Meter displays the input RF level bar graph and value and the Eb No in real time This is useful when peaking an antenna The bar graph will turn red when the level is outside the limits This display will remain until the left arrow key is pressed on the front panel ...

Страница 13: ...00092 02 Rev C 13 Advanced The Advanced menu allows navigation to Unit Setup or Unit Status Unit Setup The Unit Setup menu allows the setup of various unit parameters including decoder setup audio setup LAN settings etc ...

Страница 14: ... sent back in response to a command requesting them Serial Port Setup Navigates to the serial port setup menu which allows the user to select the function and baud rate for the port User Relay Setup Navigates to the user relay setup menu which allows the user to activate the relays Date Time Setup Navigates to the date time setup menu which allows the user to set the date time in the unit When con...

Страница 15: ...osed captioning if the mode is set to CC1 4 CC1 4 may be selected only if subtitling is disabled Composite S Video Selects video output format for the composite video outputs and S video output if available SD Aspect Ratio Selects the aspect ratio for the composite video outputs and S video output if available Component HDMI Selects video output resolution of the component and HDMI outputs when HD...

Страница 16: ...n of the audio language Choices include which is the first audio found and a list of all audio descriptors found in the transmission Audio Routing Allows routing of program audio channels Left and Right to the output connectors for the port Stereo will route left channel audio to the white output connector and right channel audio to the red output connector Or the user may select right on both or ...

Страница 17: ...CP server if one is on the network and the address assigned may be found by navigating to the unit status menu and selecting LAN IP info LAN IP Addr Allows entry of the static LAN IP address LAN IP Netmask Allows entry of the static LAN IP netmask LAN Gateway Allows entry of the LAN Gateway address Primary DNS Server Allows entry of the LAN Primary DNS server address Secondary DNS Server Allows en...

Страница 18: ...n path server typically the Compel control system Return path reports will be sent to this server Primary IP Allows entry of the primary server IP address Backup IP Allows entry of the backup server IP address Reports will be sent to this server address when the primary address is unreachable HTTP Proxy Setup Allows enabling or disabling a proxy server ...

Страница 19: ...he user to set the device assignment and baud rates of the serial port Device Assignment Assigns the serial port to terminal or printer Console Baudrate Allows selection of the baud rate to use when in terminal mode Printer BAUD Allows selection of the baud rate to use when in printer mode ...

Страница 20: ...or two relays displayed here depending upon the alarm relay usage One relay is reserved for alarms unless the user configures it to be used for user relay application This is done via the serial port in terminal mode or the diagnostics interface of the web interface The command alarmrelay user2 will assign the relay for user application and the command alarmrelay normal will assign the relay for a...

Страница 21: ...o perform best with Mozilla FireFox web browser Status view The status view displays the current status of the unit including the serial number software versions installed decoder status Compel statistics RF signal information and file download status The green LED icon will indicate the state of the LED on the unit and clicking this will show any warnings or alarms if present ...

Страница 22: ...anager view allows the user to view the assets currently on the unit Assets are user provided video audio image or text files downloaded via the Compel control system Click the assets folder to view the list of assets Assets may be viewed played or downloaded by clicking on the file name ...

Страница 23: ...2 02 Rev C 23 Logs view The logs view allows the user to view the as run log or the operational log The as run log lists all assets that have been played by the unit The operational log lists any changes in RF signal tuning ...

Страница 24: ...terface By holding down the control key on the keyboard and clicking the Wegener logo in the top left corner a diagnostics interface may be accessed From this interface in addition to many other actions the user can play a file or playlist of files from the hard disk drive ...

Страница 25: ...gnal is sent by connecting pin 5 to ground pin 9 for at least 100mS The GPIO line should be disconnected from ground after the trigger This is normally done with a momentary switch The file or playlist must be queued up for playback before the trigger is applied To queue up a file for triggered playback from the diagnostics interface enter the following into the terminal command box playfile 1 ass...

Страница 26: ...in hexadecimal This setting must match the setting in the Compel control system compel method mcast Compel will control the unit by sending commands in a multicast IP transmission The multicast IP address and port must be set by issuing the following command compel mcsetup address port where address is the multicast IP address and port is the multicast port number When using this method Compel wil...

Страница 27: ...e 25 to 65dBm Maximum Aggregate Input Power 8 dBm at max input signal Input Impedance 75 ohms Input VSWR 2 5 1 Input Noise Figure 8 dB MAX at minimum input level L O Leakage at Input 55 dBm Maximum Symbol rate DVB S 45 Mbps DVB S2 30 Msps Minimum Eb No DVB S QPSK FEC Eb No dB 1 2 4 5 2 3 5 0 3 4 5 5 5 6 6 0 7 8 6 4 DVB S2 QPSK FEC Eb No dB 1 2 1 5 3 5 2 0 2 3 2 4 3 4 2 8 4 5 3 2 5 6 3 5 8 9 4 2 9 ...

Страница 28: ...ats 1080I 60 1080I 59 94 1080I 50 720P 60 720P 59 94 720P 50 Composite Video Output iPump 562 Composite Video Output Composite Video Output Line 21 Closed captioning Divicom and ATSC EIA 608 B TELETEXT CCIR ITU R Broadcast Teletext System B Output Level 1 0 Vp p 5 Deviation Output Impedance 75 Ohms Multi burst Frequency Response NTSC From 0 5 to 4 2 MHz 0 3 dB PAL From 0 5 to 4 2 5 8 MHz 0 3 Diffe...

Страница 29: ...Frequency Response Y 5 to 25 MHz 0 3 dB Pb 2 5 to 10 MHz 0 3 dB Pr 2 5 to 10 MHz 0 3 dB iPump 562 Audio Decoder Audio Decoder Compression System MPEG 1 Layer 2 Dolby Digital MPEG2 AAC MPEG4 AAC Sample Rates Supported 44 1 and 48 kHz Audio Output iPump 562 Audio Output Unbalanced Audio Output Output level adjust range 0 to 20 dB attenuation Output Level MAX PPL 9 0 0 5 dBu Impedance Unbalanced 1000...

Страница 30: ... to 15 kHz 0 5 1 0 0 5 dB THD 0 5 S N Ratio 68 dB 22 Hz to 20 KHz unweighted Dynamic Range 86 dB unweighted Serial Port iPump 562 Serial Port Serial Port RS 232 RJ11 Selectable services Printer mode character based async output Terminal mode command line interface monitoring and control Baud Rates 2400 to 115200 baud Format 8 data bits one start one stop bit no parity ...

Страница 31: ...VDC Universal ASTRA 13 or 18 VDC polarity selection 22 KHz tone 22 kHZ control tone for LNB DRO band selection Universal ASTRA mode Current 350 mA max Short circuit protection Thermal Fuse and Foldback Regulator AC Power iPump 562 AC Power AC Power Voltage External 100 240 auto detect selected Frequency 50 or 60 Hz 2 Power consumption 40 Watts Max ...

Страница 32: ...ght 1 RU for desktop 1RU using supplied rack ears Chassis Width 16 5 inches with optional rack ears 19 inches Chassis Depth 11 5 inches Weight 7 5 lbs Front Rear Panel Labeling Chassis Finish Silver powder coat fine texture Rear panel silk screen color Gray lettering per PMS 427C Front Panel Plastic snap on bezel with 5 button switches embedded in label ...

Страница 33: ...rect or consequential damages This warranty does not cover p arts or equipment which have been subject to misuse negligence or accident by the customer during use All shipping cost s for warranty rep airs shall be prepaid by the customer There are no other warranties express or implied except as st ated herein Technical Support In the event that the unit fails to perform as described contact Wegen...

Отзывы: