4.
From the Update and Manage System Flash menu, select
Commit the
Temporary Image
and press
Enter
.
5.
When the commit function is complete, press
F3
until the Diagnostic Operating
Instructions screen is displayed; then press
F3
again to exit the diagnostic
program.
Solving shared BladeCenter resource problems
Problems with BladeCenter shared resources might appear to be in the blade
server, but might actually be a problem in a BladeCenter unit component.
This information provides procedures to help you isolate blade server problems
from shared BladeCenter resource problems.
If the problem is thought to be with a shared resource, see the online information
center or the
Problem Determination and Service Guide
or the
Hardware Maintenance
Manual and Troubleshooting Guide
for your BladeCenter unit, or see the
documentation for BladeCenter unit components for additional information. If the
problem cannot be solved, see “Solving undetermined problems” on page 231.
To check the general function of shared BladeCenter resources, complete the
following operations.
1.
Verify that the BladeCenter unit has the required power modules installed and
is connected to a working power source.
2.
Verify that power management is set correctly for your BladeCenter unit
configuration.
3.
Verify whether the problem is being experienced on more than one blade
server.
4.
Perform a test of the failing function on a blade server that is known to be
operational.
5.
Try the blade server in a different blade bay.
6.
Try a blade server that is known to be operational in the blade bay with the
failing blade server.
7.
Verify that the blade server and the monitor are powered on.
8.
Check for keyboard problems, as described in “Solving shared keyboard
problems” on page 226.
9.
Check for problems with the media tray (removable media drives and USB
ports), as described in “Solving shared media tray problems” on page 226.
10.
Check for network connection problems, as described in “Solving shared
network connection problems” on page 228.
11.
Check for power problems, as described in “Solving shared power problems”
on page 229.
Chapter 2. Diagnostics
225
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...