Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
651-734
292
Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 187.
651-735
292
Intermediate or system bus time-out error. Go to “Performing the checkout
procedure” on page 187.
651-736
292
Intermediate or system bus time-out error. Go to “Performing the checkout
procedure” on page 187.
651-740
2D3
Note:
Ensure that the system IPLROS and service processor are at the latest
firmware level before removing any parts from the system.
651-741
2D3
Service processor error accessing special registers. Go to “Performing the checkout
procedure” on page 187.
651-742
2D3
Service processor reports unknown communication error. Go to “Performing the
checkout procedure” on page 187.
651-743
2D5
Service processor error accessing Vital Product Data EEPROM. Go to “Performing
the checkout procedure” on page 187.
651-745
2D9
Service processor error accessing power controller. Go to “Performing the checkout
procedure” on page 187.
651-746
2D4
Service processor error accessing fan sensor. Go to “Performing the checkout
procedure” on page 187.
651-747
2D5
Service processor error accessing thermal sensor. Go to “Performing the checkout
procedure” on page 187.
651-748
2E2
Service processor error accessing voltage sensor. Go to “Performing the checkout
procedure” on page 187.
651-750
2D4
Service processor detected NVRAM error. Go to “Performing the checkout
procedure” on page 187.
651-751
2D4
Service processor error accessing real-time clock/time-of-day clock. Go to
“Performing the checkout procedure” on page 187.
651-752
2D4
Service processor error accessing JTAG/COP controller/hardware. Go to
“Performing the checkout procedure” on page 187.
651-753
151 2D4
Service processor detects loss of voltage from the time-of-day clock backup battery.
Go to “Performing the checkout procedure” on page 187.
651-770
292
Intermediate or system bus address parity error. Go to “Performing the checkout
procedure” on page 187.
651-771
292
Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 187.
651-772
292
Intermediate or system bus time-out error. Go to “Performing the checkout
procedure” on page 187.
651-773
227
Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 187.
651-780
2C7 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-781
2C7 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-784
302 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-785
303 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
Chapter 2. Diagnostics
147
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...