Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A03-16x
I/O Expansion unit not in an operating
state.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A05-00x
Error log analysis indicates an
environmental and power warning, but
the failure could not be isolated.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A05-01x
Sensor indicates a fan has failed.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A05-02x
System shutdown due to a fan failure.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A05-03x
Sensor indicates a voltage outside
normal range.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A05-04x
System shutdown due to voltage
outside normal range.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A05-05x
Sensor indicates an abnormally high
internal temperature.
1.
Make sure that:
a.
The room ambient temperature is within
the system operating environment.
b.
There is unrestricted air flow around the
system.
c.
All system covers are closed.
d.
There are no fan failures
2.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
3.
If no entry is found, replace the system-board
and chassis assembly.
164
JS12 Type 7998: Problem Determination and Service Guide
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...