Table 5. 1xxxyyyy SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Error Codes
Description
Action
2627
PCIE_B_PGOOD fault
Perform the DTRCARD Symbolic CRU isolation procedure by
completing the following steps:
1.
Reseat the PCIe expansion card.
2.
If the problem persists, replace the expansion card.
3.
If the problem persists, go to “Checkout procedure” on page
186.
4.
If the problem persists, replace the system board and chassis
assembly, as described in “Replacing the Tier 2 system-board
and chassis assembly” on page 274.
The DTRCARD Symbolic CRU isolation procedure is in “Service
processor problems” on page 205.
2629
1.5V reg_pgood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
262B
1.8V reg_pgood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
262C
5V reg_pgood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
262D
3.3V reg_pgood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
262E
2.5V reg_pgood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2630
VRM CP0 core pGood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
2632
VRM CP0 cache pGood fault
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
Chapter 2. Diagnostics
19
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...