Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
2604-705
2604
Error Log Analysis indicates that a parity error has been detected for the Fibre
Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data
being read or written incorrectly.
2604-706
2604
Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre
Channel adapter card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured
or the system is rebooted. This adapter must be replaced and not brought back
on-line. Failure to adhere to this action could result in data being read or written
incorrectly or in the loss of data.
2607-xxx
2607
Generic reference for 8Gb PCIe Fibre Channel Expansion Card. Go to “Performing
the checkout procedure” on page 187.
2607-102
2607
Reset Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
2607-103
2607
Register Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
2607-104
2607
SRAM Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
2607-105
2607
Internal Wrap Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe
Fibre Channel Expansion Card.
2607-106
2607
Gigabit Link Module (GLM) Wrap Test failure for the Fibre Channel adapter card.
Replace the 8Gb PCIe Fibre Channel Expansion Card.
2607-108
2607 221
Enhanced Error Handling Failure on the bus for the Fibre Channel adapter card. Go
to “Performing the checkout procedure” on page 187.
2607-110
2607
Enhanced Error Handling Failure on the Fibre Channel adapter card. Replace the
8Gb PCIe Fibre Channel Expansion Card.
2607-201
2607 221
Configuration Register Test Failure for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 187.
2607-203
2607
PCI Wrap Test Failure for the Fibre Channel adapter card. Replace the 8Gb PCIe
Fibre Channel Expansion Card.
2607-204
2607 221
DMA Test Failure for the Fibre Channel adapter card. Go to “Performing the
checkout procedure” on page 187.
2607-205
2607 221
Error on Read/Write Operation for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 187.
2607-701
2607
Error Log Analysis indicates that the adapter self-test failed for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 187.
2607-703
2607
Error Log Analysis indicates that an unknown adapter error has occurred for the
Fibre Channel adapter card. Go to “Performing the checkout procedure” on page
187.
2607-704
2607
Error Log Analysis indicates that an adapter error has occurred for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 187.
2607-705
2607
Error Log Analysis indicates that a parity error has been detected for the Fibre
Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data
being read or written incorrectly.
Chapter 2. Diagnostics
157
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...