No
Go to “Solving undetermined problems” on page 231.
Yes
Select the resources to be tested and record any SRNs; then go to
“Service request numbers (SRNs)” on page 141.
This ends the Linux procedure.
For more information about installing and using all supported operating systems,
search the IBM Support Site.
Verifying the partition configuration
Perform this procedure if there is a configuration problem with the system or a
logical partition.
1.
Check the processor and memory allocations of the system or the partition.
Processor or memory resources that fail during system startup could cause the
startup problem in the partition. Make sure that there are enough functioning
processor and memory resources in the system for all the partitions.
2.
Check the bus and virtual adapter allocations for the partition. Make sure that
the partition has load source and console I/O resources.
3.
Make sure that the Boot Mode partition properties are set to Normal.
4.
If the problem remains, contact your software service provider for further
assistance.
Running the diagnostics program
You can start or run the diagnostics program from the AIX operating system, from
a CD, or from a management server.
Starting AIX concurrent diagnostics
Perform this procedure to start AIX concurrent diagnostics from the AIX operating
system.
1.
Log in to the AIX operating system as root user, or use the CE login. See
“Creating a CE login” on page 280 for more information. If you need help,
contact the system operator.
2.
Type
diag
and press
Enter
at the operating system prompt to start the
diagnostics program and display its Function Selection menu. See “Using the
diagnostics program” on page 192 for more information about running the
diagnostics program.
3.
When testing is complete, press
F3
until the Diagnostic Operating Instructions
panel is displayed, then press
F3
to exit the diagnostic program.
Chapter 2. Diagnostics
189
Содержание BladeCenter JS12
Страница 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Страница 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Страница 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Страница 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Страница 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Страница 317: ......
Страница 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...