Error code table
In case of a malfunction of the automatic air conditioning system the display will show an error code.
Error code Fault
Cause,
Remedy
F0
• A room temperature sensor er-
ror is indicated by the flashing
display.
• Switching outputs are switched
off.
• The control unit is no longer
ready for operation.
• Check system for cable break or short-circuit, eliminate
if necessary.
• Check the correct connection of the temperature sensor
and connect if necessary.
• The cable of the temperature sensor is marked blue.
F1
• A blow-out temperature sensor
error is indicated by the flashing
display.
• Switching outputs are switched
off.
• The control unit is no longer
ready for operation.
• Check system for cable break or short-circuit, eliminate
if necessary.
• Check the correct connection of the temperature sensor
and connect if necessary.
• The cable of the temperature sensor is marked yellow.
F2
• An outside temperature sensor
error is indicated by the flashing
display.
• The control unit is still ready for
operation.
• Check system for cable break or short-circuit, eliminate
if necessary.
• Check the correct connection of the temperature sensor
and connect if necessary.
• The cable of the temperature sensor is marked red.
122
123
Содержание Leeb 5.280 VL
Страница 2: ......
Страница 5: ......
Страница 11: ...7...
Страница 199: ...Vehicle GPS antenna calibration With standard tyres VF520 85 R46 Tyre radius 915 mm Track width 195...
Страница 219: ...Diagram a with example 215...
Страница 225: ...221...
Страница 228: ...5 1 2 8 9 10 13 12 23 26 28 224...
Страница 230: ...26 39 40 42 43 45 226...
Страница 234: ...44 1 2 5 8 9 10 16 25 12 14 230...
Страница 236: ...44 50 45 44 47 48 232...
Страница 279: ...Central frame middle frame tractor link arm Parallelogram lock 275...
Страница 307: ......