179
────────────────────────────────────────────────────
:MODE
────────────────────────────────────────────────────
Syntax
:MODE
<1P2W/1P3W/3P3W/
3V3A/3P4W>
Example
When the same type of input unit is
installed in all six channels, then when
two types measurement in 3V3A mode
are desired, the combination is
⑦
.
:MODE 3V3A,3V3A
Sets channels 1 to 3 to 3V3A, and
channels 4 to 6 to 3V3A.
Syntax
:MODE?
Example
Transmission
Response
:MODE?
:MODE 3P3W,1P2W
Syntax
:PEAKhold
<ON/OFF>
Example
:PEAKHOLD ON
Enables the peak hold function.
Syntax
:PEAKhold?
Example
Transmission
Response
:PEAKHOLD?
:PEAKHOLD ON
Function
Sets the wiring mode.
Note
The only possible wiring configuration is
that shown below.
Combinations 1P3W and above require
all of the input units to be the same type.
Additionally, for clamp input units, the
current sensors in the combination must
all be of the same type and rating.
Input units not specified are all treated as
1P2W.
1ch
2ch
3ch
4ch
5ch
6ch
①
1P2W
1P2W
1P2W
1P2W
1P2W
1P2W
②
1P3W/3P3W
1P2W
1P2W
1P2W
1P2W
③
1P3W/3P3W
1P3W/3P3W
1P2W
1P2W
④
1P3W/3P3W
1P3W/3P3W
1P3W/3P3W
⑤
3V3A/3P4W
1P2W
1P2W
1P2W
⑥
3V3A/3P4W
1P3W/3P3W
1P2W
⑦
3V3A/3P4W
3V3A/3P4W
Function
Queries the current setting of wiring
mode.
Function
Enables or disables peak value hold
function.
Note
While time averaging, it is not possible to
use the peak value hold function.
Function
Queries the current setting of peak value
hold function.
:MODE
Sets the wiring mode.
:MODE?
Queries the wiring mode.
:PEAKhold
Enables or disables peak value hold function.
:PEAKhold?
Queries the peak value hold function.
Содержание Power HiTester 3193
Страница 1: ...3193 3193 10 Instruction Manual POWER HiTESTER EN Feb 2019 Revised edition 16 3193A981 16 19 02H ...
Страница 2: ......
Страница 50: ...32 3 9 Operations During Power Failure ...
Страница 76: ...58 4 13 Degaussing ...
Страница 80: ...62 5 2 Setting the Frequency Range fa ...
Страница 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Страница 112: ...94 10 3 Output Rate ...
Страница 250: ...232 13 9 Error and Overflow Displays ...
Страница 278: ...260 17 5 Internal Block Diagram ...
Страница 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Страница 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Страница 306: ...INDEX 4 Index ...
Страница 307: ......
Страница 308: ......
Страница 309: ......
Страница 310: ......