12.3 Interface Outline
────────────────────────────────────────────────────
12.3.6 Data Formats
This unit uses character string data and decimal numeric data, and the type
used varies according to the command in question.
(1) Character data
Character string data must always begin with an alphabetic character, and
the following characters can be either alphabetic characters or numerals.
Although in character data either upper case letters or lower case letters are
accepted, response messages output by this unit are always in upper case
letters.
":MEASure? U1 , I1 , P1 "
(2) Decimal data
The numeric data values are all represented in decimal, in three formats
identified as NR1, NR2 and NR3, and each of these can appear as either a
signed number or an unsigned number. Unsigned numbers are taken as
positive.
Further, if the accuracy of a numerical value exceeds the range with which
this unit can deal, it is rounded off. (5 and above is rounded up; 4 and
below is rounded down).
①
NR1 format: integer data (+12, -23, 34)
②
NR2 format: fixed point numbers (+1.23, -23.45, 3.456)
③
NR3 format: floating point numbers (+1.E-2, -2.3E+4)
The term "NRf format" includes all these three formats.
When this unit is receiving it accepts NRf format.
All of the following examples set the voltage range to 150 V:
":VOLTage1:RANGe 150"
":VOLTage1:RANGe 150.2"
":VOLTage1:RANGe 1.495E2"
When it is sending response messages it utilizes whichever one of the
formats NR1 to NR3 is indicated in the particular command.
:AVEraging:COEFficient
:BACKlight:AUTO
:CLOCK
:CURRent[ch]:RANGe
:DATAout:ITEM:EFFiciency :DATAout:ITEM:FREQuency
:DATAout:ITEM:EXTernalin :DATAout:ITEM:INTEGrate
:DATAout:ITEM:LOADfactor :DATAout:ITEM:NORMal
:DATAout:ITEM:SUM
:EXTernalin[CH]:RANGe
:FREQuency[CH]:RANGe
:INTEGrate:STARt
:INTEGrate:STOP
:INTERval:TIME
:LPF[ch]
:MATH
:MEASure:ITEM:EFFiciency :MEASure:ITEM:FREQuency
:MEASure:ITEM:EXTernalin :MEASure:ITEM:INTEGrate
:MEASure:ITEM:LOADfactor :MEASure:ITEM:NORMal
:MEASure:ITEM:SUM
:RTC:COUNt
:STIMe:STARTtime
:STIMe:STOPTtime
:TIMER:TIME
:TRANsmit:COLumn
:TRANsmit:SEParator
:TRANsmit:TERMinator
:VOLTage[ch]:RANGe
*SRE
*ESE
*ESE0
*ESE1
*ESE2
*ESE[ch]
*ESEF
Содержание Power HiTester 3193
Страница 1: ...3193 3193 10 Instruction Manual POWER HiTESTER EN Feb 2019 Revised edition 16 3193A981 16 19 02H ...
Страница 2: ......
Страница 50: ...32 3 9 Operations During Power Failure ...
Страница 76: ...58 4 13 Degaussing ...
Страница 80: ...62 5 2 Setting the Frequency Range fa ...
Страница 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Страница 112: ...94 10 3 Output Rate ...
Страница 250: ...232 13 9 Error and Overflow Displays ...
Страница 278: ...260 17 5 Internal Block Diagram ...
Страница 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Страница 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Страница 306: ...INDEX 4 Index ...
Страница 307: ......
Страница 308: ......
Страница 309: ......
Страница 310: ......