160
────────────────────────────────────────────────────
:DISPlay:SELect [number of items]
────────────────────────────────────────────────────
Syntax
:DISPlay:SELect
[4/8/16] <A,.(4, 8,
or 16 items)>
<A>: 4 items (when 4 item display)
8 items (when 8 item display)
16 items (when 16 item display)
Example
When using input unit channels 1 to 3
and 4 to 6 each for 3V3A measurement,
and measuring the power factor (
η
1):
:DISPLAY:SELECT16
U1,U2,U3,I1,I2,I3,P123,PF123,U4,
U5,U6,I4,I5,I6,P456,OFF
Sets to the 16 items display on the
Selection screen.
Display configuration
Syntax
:DISPlay:SELect
[4/ 8/ 16]
?
Response
syntax
:DISPLAY:SELECT
[4/ 8/ 16] <A>
Example
Transmission
Response
:DISPLAY:SELECT16?
:DISPLAY:SELECT16 U1,U2,U3,
I1,I2,I3,P123,PF123,U4,U5,U6,
I4,I5,I6,P456,EFF1
Function
Sets items to be displayed on the
Selection screen. If the data is not
specified, the specified selection screen is
displayed.
Errors
Execution error / If the current integration
value, power integration value, integration
elapsed time, or measurement items using
the 9605 is specified
Note
・
Separate settings can be made for four
item display, eight item display, or
sixteen item display.
・
When making the specification, the
display sequence is closed up, and
therefore it is not possible to leave some
entries blank.
・
If the setting exceeds maximum number
of set item, the data exceeded is ignored.
・
When "Pk" (waveform peak value) is
specified, the peak value which is set by
the :WAVEPeak[ch] command (switching
voltage/current) is displayed.
・
"PF" (power factor
λ
) and "DEG"
(phase angle
φ
) cannot be displayed
simultaneously. If set both, the latter is
displayed.
Function
Queries the current settings of the display
item.
:DISPlay:SELect [
number of items
]
Sets items to be displayed on the Selection screen.
4 items display
8 items display
16 items display
First item
Second item
Third item
Forth item
First item
.
.
.
.
8th item
First item
.
.
.
.
8th item
9th item
.
.
.
.
16th item
:DISPlay:SELect
[number of items]
?
Queries items to be displayed on the Selection screen.
Содержание Power HiTester 3193
Страница 1: ...3193 3193 10 Instruction Manual POWER HiTESTER EN Feb 2019 Revised edition 16 3193A981 16 19 02H ...
Страница 2: ......
Страница 50: ...32 3 9 Operations During Power Failure ...
Страница 76: ...58 4 13 Degaussing ...
Страница 80: ...62 5 2 Setting the Frequency Range fa ...
Страница 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Страница 112: ...94 10 3 Output Rate ...
Страница 250: ...232 13 9 Error and Overflow Displays ...
Страница 278: ...260 17 5 Internal Block Diagram ...
Страница 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Страница 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Страница 306: ...INDEX 4 Index ...
Страница 307: ......
Страница 308: ......
Страница 309: ......
Страница 310: ......