176
────────────────────────────────────────────────────
:MEASure:ITEM:NORMal
────────────────────────────────────────────────────
Syntax
:MEASure:ITEM:NORMal
<NR1,
(8 items)>
<NR1> = 0 - 63
Example
:MEASURE:ITEM:NORMAL 7,7,7,0,0,
0,0,0
Sets the U1, U2, U3, I1, I2, I3, P1, P2,
P3 as default items to response to the
:MEASure? query.
Syntax
:MEASure:ITEM:NORMal?
Response
syntax
:MEASURE:ITEM:NORMAL
<NR1>
Example
Transmission
Response
:MEASURE:ITEM:NORMAL?
:MEASURE:ITEM:NORMAL 7,7,7,0,0,
0,0,0
Function
Sets the default items (only measurement
value for each channels) to be transferred
in the response message to the
:MEASure? query in the default mode.
The items are set as shown below by
setting bits, to specify eight numerical
values.
bit
7
bit
6
bit
5
bit
4
bit
3
bit
2
bit
1
bit
0
1 - -
U6
U5
U4
U3
U2
U1
2 - -
I6
I5
I4
I3
I2
I1
3 - -
P6
P5
P4
P3
P2
P1
4 - -
S6
S5
S4
S3
S2
S1
5 - -
Q6
Q5
Q4
Q3
Q2
Q1
6 - -
PF6
PF5
PF4
PF3
PF2
PF1
7 - - DEG6 DEG5
DEG4 DEG3 DEG2 DEG1
8 - - PK6
PK5
PK4
PK3
PK2
PK1
Error
Execution error / If the setting data is out
of the range.
Note
The items P, S, Q, PF, DEG cannot be
selected in connection mode 3P3W or
3V3A.
Depending on the optional unit installing,
if the set items which cannot be selected
is ignored.
Function
Queries the default items to be
transferred, which are specified by the
measurement value for each channels.
:MEASure:ITEM:NORMal
Sets the output item for the normal measurement.
:MEASure:ITEM:NORMal?
Queries the output item for the normal measurement.
Содержание Power HiTester 3193
Страница 1: ...3193 3193 10 Instruction Manual POWER HiTESTER EN Feb 2019 Revised edition 16 3193A981 16 19 02H ...
Страница 2: ......
Страница 50: ...32 3 9 Operations During Power Failure ...
Страница 76: ...58 4 13 Degaussing ...
Страница 80: ...62 5 2 Setting the Frequency Range fa ...
Страница 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Страница 112: ...94 10 3 Output Rate ...
Страница 250: ...232 13 9 Error and Overflow Displays ...
Страница 278: ...260 17 5 Internal Block Diagram ...
Страница 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Страница 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Страница 306: ...INDEX 4 Index ...
Страница 307: ......
Страница 308: ......
Страница 309: ......
Страница 310: ......