H-6
F650 Digital Bay Controller
GEK-106310AB
H.1 FACTORY DEFAULT SETTINGS
APPENDIX H
H
SETPOINT > PRODUCT SETUP > DEMAND
SETTING DESCRIPTION
NAME
DEFAULT VALUE
STEP
RANGE
USER
VALUE
Function permission
Demand Function
DISABLED
N/A
[DISABLED – ENABLED]
Demand method for current values
CRNT Demand
Method
THERMAL
EXPONENTIAL
N/A
[BLOCK INTERVAL -
ROLLING DEMAND -
THERMAL
EXPONENTIAL]
Demand method for Power values
POWER Demand
Method
THERMAL
EXPONENTIAL
N/A
[BLOCK INTERVAL -
ROLLING DEMAND -
THERMAL
EXPONENTIAL]
Demand interval
Demand Interval
5 Minutes
N/A
[5 – 10 – 15 – 20– 30–60]
Trigger Enabled
Trigger Enabled
DISABLED
N/A
[DISABLED – ENABLED]
Snapshot Event generation
Snapshot Events
ENABLED
N/A
[DISABLED – ENABLED]
SETPOINT > SYSTEM SETUP > GENERAL SETTINGS
SETTING DESCRIPTION
NAME
DEFAULT VALUE
STEP
RANGE
USER
VALUE
Phase CT ratio
Phase CT Ratio
1.0
0.1
[1.0 : 6000.0]
Ground CT ratio
Ground CT Ratio
1.0
0.1
[1.0 : 6000.0]
Sensitive ground CT ratio
Stv Ground CT Ratio
1.0
0.1
[1.0 : 6000.0]
Phase VT ratio
Phase VT Ratio
1.0
0.1
[1.0 : 6000.0]
Phase VT connection
Phase VT Connection WYE
N/A
[WYE – DELTA]
Rated voltage
Nominal Voltage
100.0
0.1
[1.0 : 250.0]
Rated Frequency
Nominal Frequency
50 Hz
Hz
[50-60]
Phase rotation
Phase Rotation
ABC
N/A
[ABC – ACB]
Frequency reference
Frequency Reference
VI
N/A
[VI-VII-VIII]
Auxiliary Voltage
Auxiliary Voltage
VX
N/A
[VX – VN]
Snapshot Event generation
Snapshot Events
DISABLED
N/A
[DISABLED – ENABLED]
RELAY Out of service STATUS
RELAY OOS STATUS ENABLED
N/A
DISABLED-ENABLED
SETPOINT > SYSTEM SETUP > FLEX CURVES
FLEX CURVES A > FLEX CURVES B> FLEX CURVES C > FLEX CURVES D
SETTING DESCRIPTION
NAME
DEFAULT VALUE
STEP
RANGE
USER
VALUE
Values for reset points 0.00 pkp
Time 0.00xPKP [RST] 0.000
0.001 s
[0.000 : 65.535]
Values for reset points 0.05 pkp
Time 0.05xPKP [RST] 0.000
0.001 s
[0.000 : 65.535]
…
…
…
0.001 s
[0.000 : 65.535]
Values for reset points 0.97 pkp
Time 0.97xPKP [RST] 0.000
0.001 s
[0.000 : 65.535]
Values for reset points 0.98 pkp
Time 0.98xPKP [RST] 0.000
0.001 s
[0.000 : 65.535]
Values for operation points 1.03 pkp
Time 1.03xPKP [OP]
0.000
0.001 s
[0.000 : 65.535]
Values for operation points 1.05 pkp
Time 1.05xPKP [OP]
0.000
0.001 s
[0.000 : 65.535]
…
…
…
0.001 s
[0.000 : 65.535]
Values for operation points 19.50 pkp
Time 19.50xPKP [OP] 0.000
0.001 s
[0.000 : 65.535]
Values for operation points 20.00 pkp
Time 20.00xPKP [OP] 0.000
0.001 s
[0.000 : 65.535]
Содержание Multilin F650
Страница 9: ...8 F650 Digital Bay Controller GEK 106310AB TABLE OF CONTENTS ...
Страница 147: ...4 74 F650 Digital Bay Controller GEK 106310AB 4 3 WEB SERVER 4 HUMAN INTERFACES SETTINGS ACTUAL VALUES 4 ...
Страница 323: ...5 176 F650 Digital Bay Controller GEK 106310AB 5 13 IEC 60870 5 103 PROTOCOL CONFIGURATION 5 SETTINGS 5 ...
Страница 443: ...7 74 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 Figure 7 21 ...
Страница 457: ...7 88 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 ...
Страница 513: ...10 28 F650 Digital Bay Controller GEK 106310AB 10 18 THERMAL IMAGE ELEMENT 49 10 COMMISSIONING 10 ...
Страница 529: ...12 6 F650 Digital Bay Controller GEK 106310AB 12 4 RELAY CONFIGURATION 12 FREQUENTLY ASKED QUESTIONS 12 ...
Страница 569: ...A 36 F650 Digital Bay Controller GEK 106310AB A 1 LOGIC OPERANDS APPENDIX A A ...
Страница 735: ...C 24 F650 Digital Bay Controller GEK 106310AB C 8 ANALOG INPUTS APPENDIX C C ...
Страница 743: ...D 8 F650 Digital Bay Controller GEK 106310AB D 5 IEC 60870 5 104 POINT LIST APPENDIX D D ...
Страница 755: ...F 10 F650 Digital Bay Controller GEK 106310AB F 1 IEC 60870 5 103 PROTOCOL APPENDIX F F ...
Страница 766: ...GEK 106310AB F650 Digital Bay Controller G 11 APPENDIX G G 1 FACTORY DEFAULT LOGIC G ...
Страница 767: ...G 12 F650 Digital Bay Controller GEK 106310AB G 1 FACTORY DEFAULT LOGIC APPENDIX G G ...
Страница 801: ...I 2 F650 Digital Bay Controller GEK 106310AB I 1 GE MULTILIN WARRANTY APPENDIX I I ...