GEK-106310AB
F650 Digital Bay Controller
6-25
6 ACTUAL VALUES
6.2 STATUS
6
6.2.12.2 CONTROL EVENTS
Actual> Status > Records Status > Control Events
In this screen
Actual> Status > Records Status > Control Events
, the status of the signals configured to launch the
control events can be seen, activated or not.
The F650 provides the possibility to configure 128 control events (at
Settings>Relay Configuration > Control Events
). In
the
Actual > Records > Event Recorder > Control Events
it is possible to see and retrieve the recorded control events to
a file, seeing the text and date and time and status of the preconfigured control event.
Table 6–31: CONTROL EVENTS STATUS
6.2.12.3 OSCILLOGRAPHY
Actual> Status > Records Status > Oscillography
The following figure shows the status of the different digital channels that can be programmed to be included in
oscillography records. When the signal associated to a specific channel is active, its LED will light up on this screen.
This screen shows as well the oscillography trigger status, active or inactive, by lighting up that channel.
Table 6–32: OSCILLOGRAPHY STATUS
The last three values shown are as follows:
NUMBER OF TRIGGERS
: This is the number of the last oscillography record obtained in the relay. This value has a range
of 0 to 999.
CYCLES PER RECORD
:
This is the number of cycles contained in the oscillography record; this value depends on the
settings adjusted on the oscillography menu at
Setpoint > Product Setup > Oscillography
.
AVAILABLE RECORDS:
This is the number of available oscillography records in the relay.
Values for these last 3 fields are reset every time the oscillography settings are modified.
CONTROL EVENTS
CONTROL EVENT 1
CONTROL EVENT 2
…
CONTROL EVENT 128
OSCILLOGRAPHY
OSC DIG CHANNEL 1
OSC DIG CHANNEL 2
OSC DIG CHANNEL 3
OSC DIG CHANNEL 4
OSC DIG CHANNEL 5
OSC DIG CHANNEL 6
OSC DIG CHANNEL 7
OSC DIG CHANNEL 8
OSC DIG CHANNEL 9
OSC DIG CHANNEL 10
OSC DIG CHANNEL 11
OSC DIG CHANNEL 12
OSC DIG CHANNEL 13
OSC DIG CHANNEL 14
OSC DIG CHANNEL 15
OSC DIG CHANNEL 16
OSCILLO TRIGGER
NUMBER OF TRIGGERS
CYCLES PER RECORD
AVAILABLE RECORDS
Содержание Multilin F650
Страница 9: ...8 F650 Digital Bay Controller GEK 106310AB TABLE OF CONTENTS ...
Страница 147: ...4 74 F650 Digital Bay Controller GEK 106310AB 4 3 WEB SERVER 4 HUMAN INTERFACES SETTINGS ACTUAL VALUES 4 ...
Страница 323: ...5 176 F650 Digital Bay Controller GEK 106310AB 5 13 IEC 60870 5 103 PROTOCOL CONFIGURATION 5 SETTINGS 5 ...
Страница 443: ...7 74 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 Figure 7 21 ...
Страница 457: ...7 88 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 ...
Страница 513: ...10 28 F650 Digital Bay Controller GEK 106310AB 10 18 THERMAL IMAGE ELEMENT 49 10 COMMISSIONING 10 ...
Страница 529: ...12 6 F650 Digital Bay Controller GEK 106310AB 12 4 RELAY CONFIGURATION 12 FREQUENTLY ASKED QUESTIONS 12 ...
Страница 569: ...A 36 F650 Digital Bay Controller GEK 106310AB A 1 LOGIC OPERANDS APPENDIX A A ...
Страница 735: ...C 24 F650 Digital Bay Controller GEK 106310AB C 8 ANALOG INPUTS APPENDIX C C ...
Страница 743: ...D 8 F650 Digital Bay Controller GEK 106310AB D 5 IEC 60870 5 104 POINT LIST APPENDIX D D ...
Страница 755: ...F 10 F650 Digital Bay Controller GEK 106310AB F 1 IEC 60870 5 103 PROTOCOL APPENDIX F F ...
Страница 766: ...GEK 106310AB F650 Digital Bay Controller G 11 APPENDIX G G 1 FACTORY DEFAULT LOGIC G ...
Страница 767: ...G 12 F650 Digital Bay Controller GEK 106310AB G 1 FACTORY DEFAULT LOGIC APPENDIX G G ...
Страница 801: ...I 2 F650 Digital Bay Controller GEK 106310AB I 1 GE MULTILIN WARRANTY APPENDIX I I ...