4-60
F650 Digital Bay Controller
GEK-106310AB
4.2 HUMAN MACHINE INTERFACE (HMI)
4 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES
4
<DETAILS>
The Details screen provides access to metering values, and date and time related with the event.
The top of the screen displays a legend with the event text, followed by the date and time, the event status (ON or
OFF), and the event index number related to the complete list of events in the relay, for example (1/479). The rest of
information provided by the Details screen corresponds to the relay measures in the moment of the event. Metering
values provided in the events are secondary, and voltage values correspond to phase-to-ground voltage.
Figure 4–34: SNAPSHOT EVENTS DETAIL SCREEN
To navigate this screen the user must follow the legend at the bottom of the screen:
Enter: Meters. ESC: Prev.
: Scroll.
Intro: Meters.
To access the metering values in the moment of the event, the user must press the enter/shuttle key. A new metering
screen will be displayed, containing the primary metering values in the snapshot event, such as:
Once inside the Metering screen, a new legend will be shown for each event (Intro or ESC: Prev. U-D (L-R: Scroll); this
legend indicates that by pressing ESC or the shuttle key, the system will return to the Event Detail screen, and
pressing the up-down key or
rotating the shuttle key the user will access all the metering values contained in the
metering screen of the considered event.
ESC: Prev.
If the user presses the ESC key from the event detail screen, the system will return to the all events screen.
Phasor Ia Primary
I2 Primary
Phasor Ib Primary
Vab Primary
Phasor Ic Primary
Vbc Primary
Line Frequency Primary
Vca Primary
Phasor Ig Primary
V1 Primary
Phasor Isg Primary
V2 Primary
I0 Primary
V0 Primary
I1 Primary
3 Phase Power Factor
Ready LED ON
Date: 07/Nov/2004
St:ON
Time: 16:11:08.035
(1/479)
Phasor
Ia
Primary
0.000
Phasor Ib Primary
0.000
Phasor
Ic
Primary
0.000
Line Frequency
0.000
Phasor Ig Primary
0.000
Phasor Isg Primary
0.000
I0
Primary
0.000
I1
Primary
0.000
Enter: Meters.
ESC: Prev
: Scroll.
Содержание Multilin F650
Страница 9: ...8 F650 Digital Bay Controller GEK 106310AB TABLE OF CONTENTS ...
Страница 147: ...4 74 F650 Digital Bay Controller GEK 106310AB 4 3 WEB SERVER 4 HUMAN INTERFACES SETTINGS ACTUAL VALUES 4 ...
Страница 323: ...5 176 F650 Digital Bay Controller GEK 106310AB 5 13 IEC 60870 5 103 PROTOCOL CONFIGURATION 5 SETTINGS 5 ...
Страница 443: ...7 74 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 Figure 7 21 ...
Страница 457: ...7 88 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 ...
Страница 513: ...10 28 F650 Digital Bay Controller GEK 106310AB 10 18 THERMAL IMAGE ELEMENT 49 10 COMMISSIONING 10 ...
Страница 529: ...12 6 F650 Digital Bay Controller GEK 106310AB 12 4 RELAY CONFIGURATION 12 FREQUENTLY ASKED QUESTIONS 12 ...
Страница 569: ...A 36 F650 Digital Bay Controller GEK 106310AB A 1 LOGIC OPERANDS APPENDIX A A ...
Страница 735: ...C 24 F650 Digital Bay Controller GEK 106310AB C 8 ANALOG INPUTS APPENDIX C C ...
Страница 743: ...D 8 F650 Digital Bay Controller GEK 106310AB D 5 IEC 60870 5 104 POINT LIST APPENDIX D D ...
Страница 755: ...F 10 F650 Digital Bay Controller GEK 106310AB F 1 IEC 60870 5 103 PROTOCOL APPENDIX F F ...
Страница 766: ...GEK 106310AB F650 Digital Bay Controller G 11 APPENDIX G G 1 FACTORY DEFAULT LOGIC G ...
Страница 767: ...G 12 F650 Digital Bay Controller GEK 106310AB G 1 FACTORY DEFAULT LOGIC APPENDIX G G ...
Страница 801: ...I 2 F650 Digital Bay Controller GEK 106310AB I 1 GE MULTILIN WARRANTY APPENDIX I I ...