GEK-106310AB
F650 Digital Bay Controller
2-19
2 PRODUCT DESCRIPTION
2.4 TECHNICAL SPECIFICATIONS
2
2.4.2.9 FREQUENCY RATE OF CHANGE
2.4.2.10 LOAD ENCROACHMENT
2.4.2.11 BREAKER SETTINGS
df/dt trend
increasing, decreasing, bi-directional
df/dt pickup level
0.10 to 10.00 Hz/s in steps of 0.01
df/dt level accuracy
80 mHz/s or 3.5%, whichever is greater
Overvoltage supv.
0.00 to 110.00 % in steps of 0.01
95% settling time for df/dt
< 24 cycles
Operate time:
at 2 x pickup
12 cycles
at 3 x pickup
8 cycles
at 5 x pickup
6 cycles
Frequency Rate min.
20.00 to 80.00 Hz in steps of 0.01
Frequency Rate max.
20.00 to 80.00 Hz in steps of 0.01
Frequency Rate delay
0.00 to 60.00 s in steps of 0.01
Snapshot Events
Selectable by setting
Responds to:
Positive-sequence quantities
Minimum voltage:
0.00 to 300.00 V in steps of 0.01
Reach (sec.
Ω
):
0.02 to 250.00
Ω
in steps of 0.01
Impedance accuracy:
±3%
Angle:
5 to 50º in steps of 1
Angle accuracy:
±3º
Pickup delay:
0
.
000 to 65.535 s in steps of 0.001
Reset delay:
0.000 to 65.535 s in steps of 0.001
Time accuracy:
±3.5% or ±60 ms, whichever is greater
Operate time:
<60 ms at 50 Hz typically
Snapshot Events
Selectable by setting
Number of Switchgear
1 to 16 (selection of switchgear for breaker control)
Maximum KI
2
t
0.00 to 9999.99 in steps of 0.01 (kA)
2
s
KI
2
t integration Time
0.03 to 0.25 s in steps of 0.01 s
Maximum openings
0 to 9999 in steps of 1
Maximum Openings in one hour
1 to 60 in steps of 1
Snapshot Events
Selectable by setting
Содержание Multilin F650
Страница 9: ...8 F650 Digital Bay Controller GEK 106310AB TABLE OF CONTENTS ...
Страница 147: ...4 74 F650 Digital Bay Controller GEK 106310AB 4 3 WEB SERVER 4 HUMAN INTERFACES SETTINGS ACTUAL VALUES 4 ...
Страница 323: ...5 176 F650 Digital Bay Controller GEK 106310AB 5 13 IEC 60870 5 103 PROTOCOL CONFIGURATION 5 SETTINGS 5 ...
Страница 443: ...7 74 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 Figure 7 21 ...
Страница 457: ...7 88 F650 Digital Bay Controller GEK 106310AB 7 3 IEC 61850 CONFIGURATOR 7 IEC 61850 PROTOCOL 7 ...
Страница 513: ...10 28 F650 Digital Bay Controller GEK 106310AB 10 18 THERMAL IMAGE ELEMENT 49 10 COMMISSIONING 10 ...
Страница 529: ...12 6 F650 Digital Bay Controller GEK 106310AB 12 4 RELAY CONFIGURATION 12 FREQUENTLY ASKED QUESTIONS 12 ...
Страница 569: ...A 36 F650 Digital Bay Controller GEK 106310AB A 1 LOGIC OPERANDS APPENDIX A A ...
Страница 735: ...C 24 F650 Digital Bay Controller GEK 106310AB C 8 ANALOG INPUTS APPENDIX C C ...
Страница 743: ...D 8 F650 Digital Bay Controller GEK 106310AB D 5 IEC 60870 5 104 POINT LIST APPENDIX D D ...
Страница 755: ...F 10 F650 Digital Bay Controller GEK 106310AB F 1 IEC 60870 5 103 PROTOCOL APPENDIX F F ...
Страница 766: ...GEK 106310AB F650 Digital Bay Controller G 11 APPENDIX G G 1 FACTORY DEFAULT LOGIC G ...
Страница 767: ...G 12 F650 Digital Bay Controller GEK 106310AB G 1 FACTORY DEFAULT LOGIC APPENDIX G G ...
Страница 801: ...I 2 F650 Digital Bay Controller GEK 106310AB I 1 GE MULTILIN WARRANTY APPENDIX I I ...